8.5 Oil change
To ensure flawless operation of the machine, the oil must be changed
every 500 operating hours or at most one year after the start of operations.
The oil tank is drained by opening the bottom plug under the tank.
The filters (2 pcs.) must also be changed, because of the contaminants
extracted from the hydraulic system, which end up in the filters.
8.6 Maintenance of the valve
To withstand and operate flawlessly,
the detent end A, the spool shifter
joint B and the ball joint of the
control
valve
require
regular
lubrication.
Lubrication
of
the
valve
is
particularly important if the machine
is left standing for several months.
If the parts of the detent have
become rusty, the machine will not
operate flawlessly.
8.7 Detent end of valve
There is a small hole in the middle of the end
plate of the detent end of the valve for spraying
lubricant onto the moving parts of the valve.
Only use oil that does not congeal in frost.
The easiest way is to use a spray bottle with a
nozzle and pipe.
Insert the spray pipe in the hole and press 2-3
times for about 1-2 seconds at a time.
The oil spreads smoothly on the moving parts of
the detent end.
NOTE!
Do not use spray Vaseline because
it congeals in severe frost and the valve will not
operate properly.