Palas PAG 1000 Скачать руководство пользователя страница 14

4

  Overview of operating and display elements

14

5249-en-us_V1.2_11/20

4

Overview of operating and display
elements

LOW

HIGH

1

3

4

5

2

Overview of operating and display elements

1 Dial for setting the pump output

setpoint

4 Setpoint display

2 Dial for setting the mode

5 Indication of battery charge

or 

AC

 when plugged in to

power supply

3 Actual pump output display

Mode

Two different modes can be selected with the dial (2):

• High: maximum pump output
• Low: half of the pump output

Содержание PAG 1000

Страница 1: ...Aerosol Generator for Liquid Particles PAG 1000 Operating Manual For specialized users 5249 en us_V1 2_11 20 V1 2 ...

Страница 2: ......

Страница 3: ...vironmental conditions 11 3 5 Type plate 12 3 6 Conformity 12 3 7 Dimensions 12 3 8 Minimum clearance 13 3 9 Scope of delivery 13 3 10 Required accessories 13 3 11 Optional accessories 13 4 Overview of operating and display elements 14 5 Operation and settings 15 5 1 Transporting the device 15 5 2 Setting up the device 15 5 3 Charging the device 15 5 4 Filling glass bottle 15 5 5 Turning the devic...

Страница 4: ...Table of contents 4 5249 en us_V1 2_11 20 ...

Страница 5: ...Related documents Operating instructions aerosol generator PAG 1000 1 5 Storage of documents The storage of documents is the responsibility of the owner and or user to ensure the documents are available when they are needed Store the documents together with the device 1 6 Presentation rules The following presentations are used in this manual Text Product names and product descriptions Example Fida...

Страница 6: ...1 About this manual 6 5249 en us_V1 2_11 20 32 Reference to page number Example For further information see the section Technical data 12 ...

Страница 7: ... the device 1 Do not use the device in a flammable or explosive environment e g rich in hydrogen or oxygen 2 Do not use the device with flammable or explosive carrier gases e g rich in hydrogen or oxygen Safe operation of the device 1 Operate the device only when it is connected to an electrical outlet with residual current circuit breaker 2 Only operate the device with the insulation and or casin...

Страница 8: ...s not avoided Meaning of the pictographs DANGER Warnings with information about the severity of the hazard DANGER Danger to life due to electric shock NOTICE Damage to property 2 3 Regulations Observe the following regulations and directives Statutory regulations Legal regulations for accident prevention Legal regulations for environmental protection Employer s Liability Insurance Association prov...

Страница 9: ... 2_11 20 9 4 Make sure that the required inspections and maintenance tasks are carried out 5 Have the device serviced by the manufacturer or an authorized distributor 6 Have damage to the device repaired promptly by the manufacturer ...

Страница 10: ...y applications The device is not intended for use by the following persons Persons with limited physical sensory or mental abilities Persons lacking experience or knowledge Children under 16 years of age These persons must be supervised by a person responsible for their safety or previously instructed in the use of the device Children must be supervised to prevent them from playing with the device...

Страница 11: ...nctional description The PAG 1000 generates an aerosol with a particle concentration up to 4 7 x 107 particles cm3 An integrated pump generates the compressed air A vacuum conveys the fluid to be nebulized through a Laskin nozzle The size and concentration of the particles generated are a factor of the fluid used as well as of the pump settings The volume flow rate can be set between 0 9 and 4 6 l...

Страница 12: ...erature range 0 to 40 C Humidity 95 Operation and storage under other environmental conditions for instance in corrosive or explosive environments powerful electrical or electromagnetic fields areas with ionizing radiation or areas subject to shocks and vibrations is prohibited 3 5 Type plate The type plate is on the back of the device behind the glass bottle 1 4 2 5 3 Type plate 1 Type designatio...

Страница 13: ...ered equipment for damage and completeness The scope of delivery includes Aerosol generator PAG 1000 Glass bottle Power supply unit Outlet nozzle POM black for saline solutions Cover ring POM black for saline solutions Operating instructions 3 10 Required accessories DEHS or similar as working fluid Isopropyl for purging and cleaning the device 3 11 Optional accessories The following accessories a...

Страница 14: ...rview of operating and display elements 1 Dial for setting the pump output setpoint 4 Setpoint display 2 Dial for setting the mode 5 Indication of battery charge or AC when plugged in to power supply 3 Actual pump output display Mode Two different modes can be selected with the dial 2 High maximum pump output Low half of the pump output ...

Страница 15: ...ion slots on the rear of the housing are not obstructed at any time 5 3 Charging the device The device has to be charged before using it for the first time or when the battery is dead The display shows the charge level of the device 4 Use only the power supply unit delivered with and belonging to the device The power supply unit heats up slightly while charging Charge time It takes 2 5 h for the d...

Страница 16: ...ume flow rate approx 4 6 l min The measurable particle number concentration and the measurable particle stream depend on the lower detection limit of the measuring device used Particle number concentration Lower detection limit of measuring device µm Minimum volume flow rate Maximum volume flow rate Measurable particles particles cm3 Measurable particles particles cm3 0 02 2 2 103 4 7 107 0 2 1 3 ...

Страница 17: ...ozzle is suitable for DEHS and similar viscous oils If aerosols are to be generated from saline solutions an outlet nozzle made of POM black with associated cover ring must be installed These parts are supplied with the device For the conversion you need an open end wrench with the wrench size 14 Part no of the component Name of the component Suitable for 3104 Outlet nozzle stainless steel DEHS oi...

Страница 18: ...ass bottle 4 Screw the glass bottle into the device 5 Switch on the device ans allow it to run for 15 minutes on High at setpoint 100 6 Switch off the device 7 Empty the isopropyl out of the glass bottle 8 Allow all components to dry Cleaning housing You can wipe the outside of the device with a damp cloth Only use water for cleaning Do not use abrasive cleaners Maintenance by the manufacturer Mai...

Страница 19: ...tion Package the device securely to exclude damage during transportation Original packaging For the purpose of shipping use the original packaging including the protective inner packaging or the original transport case if applicable If you no longer have the original packaging use packaging that securely protects the device against detrimental influences during transportation Detrimental influence...

Страница 20: ...transport packaging at collection points 4 Observe the applicable national regulations Device and accessories The device and accessories must not be disposed of in household waste 1 Ensure that the used device and any accessories are properly disposed of 2 If a battery is installed in the device make sure that it is properly disposed of 3 Observe the applicable national regulations ...

Страница 21: ...9 Spare parts 5249 en us_V1 2_11 20 21 9 Spare parts Art no Designation 1619 Glass bottle 100 ml 3639 Power supply unit PAG 1000 ...

Страница 22: ...10 Declaration of conformity 22 5249 en us_V1 2_11 20 10 Declaration of conformity ...

Страница 23: ... similarly viscous oils saline solutions 5 Maximum filling quantity 80 ml Aerosol outlet connection Øouter 8 mm Øinner 7 mm Electrical power supply unit connection 115 230 V 50 60 Hz mains operation Power consumption 20 W Battery operation Approx 8 h operating time 5200 mAh capacity Dimensions 215 165 220 mm H W D Weight Approx 5 kg Housing Stainless steel Ambient temperature operation 0 40 C Nois...

Страница 24: ...Palas GmbH Greschbachstraße 3 b 76229 Karlsruhe Germany Tel 49 721 96213 0 Fax 49 721 96213 33 www palas de mail at palas de ...

Отзывы: