Paladin Tools 1573 Скачать руководство пользователя страница 2

Paladin Tools

®

6. For best results, use “Dual” for balanced line toning, and “Single” for 
unbalanced line toning. Press and hold the “TONE” button to change tone 
patterns.
7. Use the tone probe to detect tone signals along the cable length. Press and 
hold the “TRACE” button to activate the tone probe. The “Power” light will 
turn on when button is depressed. Use the “volume” adjustment located on 
the side of the tone probe to set volume to desired level.
8. For quiet operation, insert standard 3.5 mm head phones into the headset 
socket located on the side of the probe.
9. Set “tlk, cont, line/tone” switch on side of tone generator to the “cont” 
position when storing. Leaving the switch in the “line/tone” position will 
not cause any battery drainage unless the metal tips of the red and black 
alligator clips touch

.

Testing phone circuit polarity:

WARNING! LIVE CIRCUIT TESTING - USE CAUTION

ENSURE THE TONE GENERATOR IS TURNED OFF

1. For testing directly into RJ11 wall jacks, use the RJ11 patch cord wired 1-to-1 

connection.Connect the RJ11 patch cord into the top of the tone generator in the  
RJ11 socket. (Proceed to Step 4).

2. For testing telephone boxes, discrete wire connections or open contact 

connections, install the alligator clip cable provided into the top of the tone 
generator in the RJ11 socket. (Proceed to Step 4).

3. To test RJ45 systems, use the RJ11-to-RJ11 patch cord provided to connect into 

the top of the tone generator in the RJ11 socket. 

An RJ11 plug is compatible to 

insert into most RJ45 sockets

. The tone will be applied to the RJ45 two center 

pins #4 and #5 respectively. In the event the RJ11 plugs on the patch cord is not 
compatible with the RJ45 socket, use an RJ11-to-RJ45 adapter patch cable (

not 

provided

) ensuring the two center pins for the RJ11 plug are mated to the two 

center pins of the RJ45 plug, or use an 8-way RJ45 Modular Adapter (also known 
as a banjo) such as the Paladin Tools model 1902 (

Modular Adapter is not provided

).

4. Set the “tlk, cont, line/tone” slide switch located on the side of the tone 

generator to the “line/tone” position.

5. If the polarity for the TIP and RING is correct, the “Normal” light will turn on. If   

the polarity for the TIP and RING is reversed, the “Reverse” light will turn on.

6. Perform steps 4 and 5 to check line status. If the line is not in use, the “Normal” 

or “Reverse” lights will be brightly lighted. If the line is in use, the “Normal” or 
“Reverse” lights will be dim. If the line is ringing, the “Normal” or “Reverse” lights 
will flash.

Single

Dual

Rev

Norm

Polarity Testing
Normal Polarity

Single

Dual

Rev

Norm

Polarity Testing
Reverse Polarity

Examples: Test Results 

and Indications

LAN & Telecom Cable Testing Kit

1573

Polarity Testing

Normal Polarity

Polarity Testing

Reverse Polarity

Reverse

Reverse

Normal

Normal

Dual

Dual

Single

Single

Paladin Tools

®

Testing Continuity of Lines and Loads: 

DO NOT USE ON LIVE CIRCUITS

ENSURE THE TONE GENERATOR IS TURNED OFF

1. Install the alligator clip cable into the top of the tone generator.
2. Set the “tlk, cont, line/tone” slide switch located on the side of the tone 

generator to the “cont” position.

3. Connect the alligator clip test leads to the ends of the cable or across the 

load to be tested. 

4. If the DC resistance (continuity) of the cable or load is 12000

(12K

) or 

less, the “Reverse” light will turn on indicating a path of continuity.

5. Set the “tlk, cont, line/tone” switch on side of tone generator to the “cont”

position when storing. Leaving the switch in the “line/tone” position will 
not cause any battery drainage unless the metal tips of the red and black 
alligator clips touch.

Talk Power/Battery Power for Butt Set Communications

DO NOT USE ON LIVE CIRCUITS

ENSURE THE TONE GENERATOR IS TURNED OFF

1. Install the alligator clip cable into the top of the tone generator.
2. Connect the alligator clips so the tone generator is in series with the butt 

set at one end of the dead pair.

3. Connect a second butt across the dead pair at the opposite end of the line.
4. Set the “tlk, cont, line/tone” slide switch located on the side of the tone 

generator to the “tlk” position.

5. Take both butt sets off “hook” open communications.
6. Set “tlk, cont, line/tone” switch on side of tone generator to the “cont” 

position when storing. Leaving the switch in the “line/tone” position will 
not cause any battery drainage unless the metal tips of the red and black 
alligator clips touch.

Single

Dual

Rev

Norm

Continuity Testing
Good Continuity

Single

Dual

Rev

Norm

Continuity Testing
No Continuity/High Res.

Examples: Test Results 

and Indications

LAN & Telecom Cable Testing Kit

1573

Continuity Testing
Good Continuity

Continuity Testing
No Continuity/High Res.

Reverse

Reverse

Normal

Normal

Dual

Dual

Single

Single

NOTES:

NOTES:

connectool Inc. - USA • Support: 800.272.8665 • Int’l 001.804.550.1121 • web: paladin-tools.com • 06/05

connectool Inc. - USA • Support: 800.272.8665 • Int’l 001.804.550.1121 • web: paladin-tools.com • 06/05

Отзывы: