User Manual for Pakton Electric Fence Remote Monitor Series
15/10/09
Page 11 of 18
The cables shown should enter the enclosure of the Electric Fence Monitor through the
cable gland on the side. The connections to the electric fence are not shown in Figure 1
because those cables are terminated at the binding posts outside the Electric Fence
Monitor’s enclosure.
For security applications the Electric Fence Monitor can be configured for either Stand
Alone or Alarm Panel Operation.
Stand Alone Operation
In Stand Alone Operation, the relay outputs can be used to switch a siren or a strobe on
when an alarm condition is raised. If both a siren and a strobe is desired, they can be
connected in parallel (provided the power supply or battery is big enough to power both).
Figure 2 - Stand Alone Operation
Alarm Panel Operation
In Alarm Panel Operation, the relay outputs are connected to the alarm panel. See the
documentation supplied with the Alarm Panel.
Figure 3 - Alarm Panel Operation
Battery or
power pack.
Alarm Panel
Battery or
power pack.