Pakon Part#125384-A
February 9, 2005
19
9. Re-attach the fan cover by applying moderate pressure to each of the four sides, until it snaps
back in to place.
Cleaning the Film Track
It is recommended to clean the film track every two weeks, along with the illumination
cleaning. Keeping the film track clean will ensure that DX code reading remains reliable. It will
also maintain the proper motor speed for each resolution.
1. Remove the film path cover.
2. Position the tip of the compressed air hose on both sides of the film track entrance, and blow.
3. Position the tip of the compressed air hose on both sides of the film track exit, and blow.
4. After cleaning the film track, run the ‘Film Track Test’ in the client interface program.
5. Verify the scanner is properly reading DX codes by scanning a roll of film.
Содержание F-335 Series