7 .. 28 VDC PELV or SELV
2x1.5V batteries
Technical Specifications
Power Supply
PELV: 5mW, max. 50mW
Battery: 10
μ
W, max. 30mW
Power Consumption
50mW at PELV or SELV
Total Power Loss
IP20
Safety Rating
-40 ... 85°C / -40 ... 185°F
Energizer Max Plus battery:
-18 ... 55°C
Ambient temperature
max. 95% r. H. (non condensing)
Humidity
868MHz (SRD Band Europe)
max. Power 15.1mW e.r.p.
915MHz (ISM Band Region 2)
Radio Frequency
0.25 ... 0.8mm2 /
AWG23 ... AWG18
Wire cross-section
5mm / 0.2”
Stripping Length
To make connection, insert wire;
to remove the wire, twist and pull
at the same time.
Push-In-Technology
Cennection Push Terminal
Contains FCC ID: 2ARRV-000375
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1.
This device may not cause harmful interference
2.
This device must accept any interference received,
including interference that may cause undesired operation