NK-1 Wireless Controller User Guide

 

15

 

 

 

 

To prevent electric shock, do not remove the cover of this product. There are no user-

serviceable parts inside. This unit contains hazardous voltages and should only be opened 

by a trained and qualified technician. 

 

Do not work on equipment or cables during periods of lightning activity. 

 

Check to see if there are any exposed copper strands coming from the installed wire. When 

this installation is done correctly there should be no exposed copper wire strands 

extending from the terminal block. Any exposed wiring can conduct harmful levels of 

electricity to persons touching the wires. 

 

The power source for the device should be located near the unit and should be easily 

accessible. 

 

Circuit Overloading: Consideration should be given to the connection of the equipment to 

the supply circuit and the effect that overloading of circuits might have on overcurrent 

protection and supply wiring. Appropriate consideration of equipment nameplate ratings 

should be used when addressing this concern. 

Rack-mount safety precautions 

For your protection, observe the following rack-mount safety precautions when setting up your 

equipment: 

 

Elevated operating ambient - If installed in a closed or multi-unit rack assembly, the 

operating ambient temperature of the rack environment may be greater than room 

ambient. Therefore, consideration should be given to installing the equipment in an 

environment compatible with the maximum ambient temperature (Tma) specified by the 

manufacturer. 

 

Reduced air flow - Installation of the equipment in a rack should be such that the amount 

of air flow required for safe operation of the equipment is not compromised. 

 

Mechanical loading - Mounting of the equipment in the rack should be such that a 

hazardous condition is not achieved due to uneven mechanical loading. 

 

Circuit overloading - Consideration should be given to the connection of the equipment to 

the supply circuit and the effect that overloading of the circuits might have on overcurrent 

protection and supply wiring. Appropriate consideration of equipment nameplate ratings 

should be used when addressing this concern. 

 

Reliable earthing - Reliable earthing of rack-mounted equipment should be maintained. 

Particular attention should be given to supply connections other than direct connections to 

the branch circuit (for example, use of power strips). 

 

For safety, equipment should always be loaded from the bottom up. That is, install the 

equipment that will be mounted in the lowest part of the rack first, then the next higher 

systems, etc. 

 

To prevent the rack from tipping during equipment installation, the anti-tilt bar on the rack 

must be deployed. 

 

The mounting brackets provided must be used to securely mount the device in a rack-

mount unit. 

Ordering information 

Part number 

Description 

S3L-24P 

S3L-24P Layer 3 Lite Managed Switch. 
24 copper PoE ports with 10/100/1000Mbps wire-speeds. 
4 SFP+ module ports with 1/10 Gbps wire-speeds. 

Содержание S3L-24P

Страница 1: ...S3L 24P Layer 3 Lite Managed Switch Hardware Installation Guide...

Страница 2: ...re installation 6 Installation guidelines 6 Installation into a rack 6 Installing transceivers into the transceiver ports 8 Software features 9 Layer 2 features 9 Service access control 10 Layer 3 fea...

Страница 3: ...ch Web User Interface Guide S3L 24P Layer 3 Lite Managed Switch Command Line Interface Guide Typographical conventions Throughout this document certain typographical conventions will be used to either...

Страница 4: ...over Ethernet PoE ports and four 1 10Gbps SFP module ports This switch supports the latest IEEE 802 3az Energy Efficient Ethernet EEE standard to save power while links are online or to notify select...

Страница 5: ...witch feature the following LED indicators Figure 2 Front panel LED Indicators Figure 3 Back panel LED Indicators The following table lists the LED indicators available on the front and back panels of...

Страница 6: ...4 Back panel The following table lists the physical ports and buttons available on the back panel of the switch Label Description AC INPUT One AC power receptacle IEC 60320 C14 One electrical groundi...

Страница 7: ...each side panel Three ventilation fans Heat dissipation vents on each side panel Note For more information about rack mount installation refer to Installation into a Rack This switch has a built in t...

Страница 8: ...onal equipment needed to install the switch into a rack mount unit One Phillips head screwdriver This screwdriver will be used for the rack mount bracket screws One additional screwdriver This screwdr...

Страница 9: ...screwdriver to fasten the frontal rack mount brackets onto the front of the rack mount unit Figure 7 Installing switch in rack mount unit Note Make sure that there is adequate space around the switch...

Страница 10: ...are excellent Connectivity can be established from the SFP ports to 10 Gigabit Ethernet switches or hosts using a fiber copper cable that has an SFP transceiver on one end and an SFP transceiver on t...

Страница 11: ...PAN and ERSPAN Quality of Service bandwidth control queues and priority tag remarking VLAN 802 1Q VLAN auto voice VLAN MAC based VLAN port based VLAN private VLAN protocol based VLAN and subnet VLAN I...

Страница 12: ...e based 802 1X sessions RADIUS authentication and unauthenticated VLAN guest VLAN DHCP server filtering Layer 3 features Category Feature Layer 3 table IP optimized host prefixes up to 512 IPv4 or 256...

Страница 13: ...imple Network Management Protocol SNMPv1 SNMPv2c and SNMPv3 Simple Network Time Protocol SNTP Secure Shell SSHv2 Secure Sockets Layer SSLv2 and SSLv3 Static ARP table configuration System monitoring e...

Страница 14: ...KEDGE DHCP SNOOPING MIB PAKEDGE DYNAMIC ARP INSPECTION MIB PAKEDGE DOS PREVENT MIB PAKEDGE MGMD MIB PAKEDGE DHCP RELAY MIB PAKEDGE SSH MIB PAKEDGE TIME CONFIGURATION MIB PAKEDGE VLAN INTERFACE MIB Man...

Страница 15: ...af PoE support Yes supplies 15 4 watts per port IEEE 802 3at PoE support Yes supplies 30 watts per port Automatic PD discovery Yes will supply power immediately if PD device was detected PoE safety Au...

Страница 16: ...structed on the reasons for the restrictions and any precautions that need to be taken Remove all metal jewelry such as rings and watches before installing or removing the device Do not look directly...

Страница 17: ...given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced air flow Installation of the equipment in a rack should be...

Страница 18: ...information pakedge com regulatory Copyright 2017 Control4 Corporation All rights reserved Control4 the Control4 logo Pakedge and BakPak are registered trademarks or trademarks of Control4 Corporation...

Отзывы: