150-231-184-05, Revision 05
Provisioning
HLU-231 List 8D
October 25, 1999
21
describes the System Settings options and lists the corresponding codes. Most of these options must be
configured through the Maintenance Terminal System Settings screen. EQL, LBTO, LNCD, and CONF can also
be set using the MODE and SEL buttons. Factory default parameters appear in boldface type.
Table 8.
HLU-231 List 8D System Settings
System Settings
Screen Options
Code
Parameter
Description
Equalization
(a)
EQL
EXT
Disables the HLU internal equalizer, allowing connection of external equalizer
hardware to perform the same or a similar function.
0
Sets the Equalizer to DSX-1 for 0 to 133 feet.
133
Sets the Equalizer to DSX-1 for 133 to 266 feet.
266
Sets the Equalizer to DSX-1 for 266 to 399 feet.
399
Sets the Equalizer to DSX-1 for 399 to 533 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
SmartJack Loopback LBPK
DIS
Configures the HiGain system to ignore all inband SmartJack loopback
commands.
ENA
Enables the HiGain system to recognize all inband SmartJack loopback
commands.
Power
PWRF
DIS
Disables powering to the HDSL pair.
(See
.)
LOW
Keeps the HDSL line voltage at -140 V maximum for all applications.
AUTO
Allows the HDSL line voltage to automatically switch between -140 V
maximum for non-doubler applications and ±112 V for doubler applications.
HIGH
Forces the HDSL line voltage to ±112 V for all applications.
BER Alarm
Threshold
BERT
1E-6
Activates (closes) the system alarm relay contacts on pins 20 and 21 of the
card-edge connector and flashes the red Status LED when the BER exceeds
10
-6
.
(See
.)
1E-7
Activates (closes) the system alarm relay contacts on pins 20 and 21 of the
card-edge connector and flashes the red Status LED when 10
-6
> BER >10
-7
.
NONE
Prevents generation of a system alarm due to BER.
Loopback Timeout
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
Alarm
ALM
DIS
Opens the system alarm relay contacts if closed, and disables activation of the
system alarm relay when a system alarm condition occurs.
ENA
Enables activation of the system alarm relay when a system alarm condition
occurs.
DSX-1 Line Code
LNCD
B8ZS
Places both the HLU-231 and HRU into their B8ZS modes.
AMI
Places both the HLU-231 and HRU into their AMI modes.
AIS on SMJK/NREM
SAIS
ENA
Causes the HRU to transmit the AIS signal towards the Customer Interface
(CI) when in NREM or SmartJack loopback.
DIS
Causes the HRU to either transmit the signal from the network towards the CI
RCV port or to open and terminate its RCV CI port when an HRU NREM or
SmartJack loopback is executed. The AIS signal is not sent (towards the CI).
Margin Alarm
Threshold
(See
.)
MARG
0 to 15 dB
The Margin Alarm Threshold can only be set through a maintenance terminal
connected to the craft port. It determines the minimum allowable margin
below which a system alarm can occur. Zero disables the alarm.
4dB
Default value.