150-231-184-05, Revision 05
Provisioning
HLU-231 List 8D
October 25, 1999
19
Set Clock Screen
Press
at the Maintenance Terminal Main Menu to open the Set Clock screen (
Figure 7.
Set Clock Screen
Set Time
The cursor defaults to the New Time field. To set the system time, type the hour and minute in the 24-hour format
of hh:mm:ss (setting the seconds is optional), then press
. The New Date field appears.
Set Date
To set the system date, type the month, day and year in a mm/dd/yy format, then press
. The Update
Remote field appears.
Update the HRU Date and Time
Use this option to set the remote unit date and time:
•
Press
to update the HRU to the same date and time set for the HLU-231 List 8D.
•
Press
. (The remote unit is not updated.)
Time information is lost when power is removed. The last date, however, is retained in NVRAM
and reappears when power is restored.
When editing entries in the Set Clock screen and when using the Terminal emulation program
in Windows 3.1, pressing the
key deletes two characters instead of just one.
B
SET CLOCK
TIME: 00:14:33
DATE: 10/08/99
CIRCUIT ID#:
Format: HH:MM
MM/DD/YY
NEW TIME:
NEW DATE:
(U)PDATE REMOTE?
ENTER
ENTER
BACKSPACE
U
ENTER