7.  FRONT PANEL

7.01

The front panel of the FLC-752 Channel Unit
contains the following indicators (see Figure 1):

• 

ACTIVE 1, 2, 3, 4 LED Indicators

Green—the channel is off-hook.

Flashing Green—the channel is ringing (the LED
will track the ringing) or the line has been switched
to the test pair.

Off—the channel is on-hook.

• 

FAULT LED Indicator

Red—a fault has been detected on the unit.

Off—no faults are detected on the unit.

C. INSTALLATION AND TEST

8.  UNPACKING

8.01

Upon receipt of the equipment, proceed as follows:

1.

Unpack each container and visually inspect
it for signs of damage. If the equipment has

been damaged in transit, immediately report the
extent of damage to the transportation company
and to PairGain. Order replacement equipment
if necessary.

2.

Check the contents versus the packing list to
ensure complete and accurate shipment. If the
shipment is short or irregular, contact PairGain
as described in Section 5. If you must store the
equipment for a prolonged period, store the
equipment in its original container.

9.  TURN-UP AND TESTING

9.01

Table 2 provides step-by-step turn-up and test
procedures for the FRC-752 Channel Unit.

10.  TROUBLESHOOTING

10.01

Table 3 provides troubleshooting procedures based
on indications displayed by the front panel

indicators of FRC-752 Channel Unit.

TABLE 2.  FRC-752 RT CHANNEL UNIT TURN-UP AND TESTING

CAUTION

Observe normal electrostatic discharge precautions when handling electronic equipment. Do not hold electronic plug-ins

by their edges. Take care not to touch components or circuitry.

Step

Operation

Action

Observe

1

Install RT
Channel
Units

a.  Insert each FRC-
752 Channel Unit
into the FRE-765 RT
Enclosure.

All LEDs on the Channel Unit will turn on for approximately 2 seconds, then scan
from top to bottom, then turn off.

b.  After the system
has powered up,
established HDSL
synchronized
communications, and
no calls are in
progress, observe the
Channel Unit front
panel indicators.

ACTIVE 1 

off

ACTIVE 2 

off

ACTIVE 3 

off

ACTIVE 4 

off

FAULT 

off

2

Test
Subscriber
Circuits

a.  Test each
subscriber circuit by
placing and receiving
calls.

ACTIVE 1 through 4 LEDs track call as described in paragraph 7.01.

Содержание PG-FLEX RT FRL-752

Страница 1: ...NS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 4 5 WARRANTY 4 B FUNCTIONAL DESCRIPTION 6 OPERATIONAL CAPABILITIES 4 7 FRONT PANEL 5 C INSTALLATION AND TEST 8 UNPACKING 5 9 TURN UP AND TESTING 5 10 TROUBLESHOOTING 5 CAUTION This product incorporates static sensitive components Proper electrostatic discharge procedures must be followed Figure 1 FRC 752 Channel Unit List 1 Front Panel The PairGain FRC 752 p...

Страница 2: ...emote electronics and subscriber terminations The enclosure accepts one common RT Line Unit and up to four Channel Units The Remote Terminal communicates with and is line powered from the COT over two pairs of 19 to 26 gauge 0 9 mm to 0 4mm twisted pair telephone wire Each pair carries both power and HDSL signaling 2 03 HDSL Transmission PG Flex utilizes HDSL transmission technology between the CO...

Страница 3: ...t Drive 15 REN maximum per RT 5 REN maximum per channel RT DC Supervisory Range 960 ohms Maximum cable loop resistance minus 430 ohms for handset is 530 ohms RT Idle State Loop Voltage On Hook Greater than 40 V dc Ring is negative with respect to Tip RT Loop Closure Off Hook Detection Less than 960 ohms between Tip and Ring RT On Hook Detection Greater than 10 kohms Operating Temperature Humidity ...

Страница 4: ...and regular maintenance PairGain will repair or replace any unit without cost during this period if the unit is found to be defective for any reason other than abuse or improper use or installation 5 02 This module should not be field repaired If it fails replace it with another unit and return the faulty unit to PairGain for repair Any modifications of the unit by anyone other than an authorized ...

Страница 5: ...for a prolonged period store the equipment in its original container 9 TURN UP AND TESTING 9 01 Table 2 provides step by step turn up and test procedures for the FRC 752 Channel Unit 10 TROUBLESHOOTING 10 01 Table 3 provides troubleshooting procedures based on indications displayed by the front panel indicators of FRC 752 Channel Unit TABLE 2 FRC 752 RT CHANNEL UNIT TURN UP AND TESTING CAUTION Obs...

Страница 6: ...ance shorts on the subscriber drop 2 If ringing isn t present on a circuit terminated on the same RT Channel Unit try ringing a line terminated on another RT Channel Unit If the line rings replace the RT Channel Unit If the line doesn t ring replace the RT Line Unit Phone Doesn t Stop Ringing Faulty subscriber station instrument faulty RT Channel Unit or loop length too long Phone stops ringing wh...

Отзывы: