background image

Revision 02

January 12, 1998

Section 363-704-102-02

PG-Flex FLC-704 List 2

PairGain Engineering - Plant Series

Page 9

D. TECHNICAL SUPPORT

9.  Technical Support

9.1

PairGain Technical Assistance is available 24-hours-a-day, 7-days-a-week by contacting PairGain
Customer Service Engineering group at:

Telephone:

(800) 638-0031 or (714) 832-9922

Fax:

(714) 832-9924

9.2

During normal business hours (8:00 AM to 5:00 PM, Pacific Time, Monday - Friday, excluding
holidays), technical assistance calls are normally answered directly by a Customer Service Engineer.
At other times, a request for technical assistance is handled by an on-duty Customer Service
Engineer through a callback process.  This process normally results in a callback within 30 minutes
of initiating the request.

9.3

In addition, PairGain maintains a computer bulletin board system for obtaining current information
on PairGain products, product troubleshooting tips and aids, accessing helpful utilities, and for
posting requests or questions.  This system is available 24-hours-a-day by calling (714) 730-3299.
Transmission speeds up to 28.8 kbps are supported with a character format of 8-N-1.

E.  CERTIFICATION AND WARRANTY

10.  Certification

10.1

FCC Compliance. The FLC-704 List 2 Channel Unit complies with the limits for Class A digital
devices pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.

10.2

Refer to the installation section of the appropriate instruction manual for the unit you are installing to
get information on:

cabling

proper connections

grounding

line power

10.3

All wiring external to the product(s) should follow the provisions of the current edition of the
National Electrical Code.

Содержание PG-Flex 8 FLC-704

Страница 1: ...704 Model List Number Part Number CLEI Code FLC 704 2 150 1304 02 N A PAIRGAIN TECHNOLOGIES INC ENGINEERING PLANT SERIES TECHNICAL PRACTICE SECTION 363 704 102 02 Revision History of this practice Re...

Страница 2: ...S TECHNICAL PRACTICE Two types of messages identified by icons appear in the text A note informs you of special circumstances Cautions indicate the possibility of damage to equipment or the possibilit...

Страница 3: ...C 704 Channel Unit includes green status LEDs for each line indicating idle ringing and off hook conditions as well as a red LED indicating a fault condition The channel unit provides metallic test ac...

Страница 4: ...dications for the FLC 704 Channel Unit front panel LEDs Figure 1 FLC 704 Front Panel Table 1 FLC 704 Front Panel LEDs LED LED State Indicates Solid green Channel is off hook ACTIVE Fast flashing green...

Страница 5: ...OT End to End Loss 2 5 dB 1 0 DC Off Hook Current 30 mA Channel Signature Tip Ring 475 k 1 Tip Ground 332 k 1 Ring Ground open COT 20 Hz Input Impedance 0 5 REN Environmental Operating Elevation 200 f...

Страница 6: ...Group 3 facsimile or high speed modem operation on all channels 4 2 System Flex Configuration Figure 2 shows a typical PG Flex system that consists of COT Two complete systems may be installed in a 19...

Страница 7: ...the HDSL lines do not require any special conditioning and may include unterminated bridge taps but cannot include load coils Table 2 PG Flex Distances Loop Length Wire Gauge 16 32 Channel System Res...

Страница 8: ...rd disconnect detects a subscriber test access signal detects metering tones provides loop closure 5 2 A block diagram of the FLC 704 Channel Unit is shown in Figure 3 One 8 Channel COT Channel Unit s...

Страница 9: ...re the equipment for a prolonged period store the equipment in its original container 7 Turn Up and Testing 7 1 Install COT Channel Units 1 Insert each FLC 704 Channel Unit into the COT shelf All LEDs...

Страница 10: ...resent at the RT re insert the original Channel Unit and Line Unit Test for ringing at the COT 4 Test for ringing into the COT from the CO switch If no ringing is present refer the trouble to the CO s...

Страница 11: ...uestions This system is available 24 hours a day by calling 714 730 3299 Transmission speeds up to 28 8 kbps are supported with a character format of 8 N 1 E CERTIFICATION AND WARRANTY 10 Certificatio...

Страница 12: ...ranty 11 3 If a unit needs repair call PairGain for a Return Material Authorization RMA number and return the defective unit freight prepaid along with a brief description of the problem to PairGain R...

Страница 13: ...Revision 02 January 12 1998 Section 363 704 102 02 PG Flex FLC 704 List 2 PairGain Engineering Plant Series Page 11...

Страница 14: ......