background image

350-431-116-01, Revision 01

Product Overview

HLU-431 List 1F

January 8, 1999

 3

Table 1.

Front Panel Features

Features

Function

Front panel display

Displays four-character status, provisioning, and alarm system 
messages.

System option buttons 
(MODE and SEL)

Permits the user options to be monitored and modified without 
the need of a maintenance terminal. Used to initiate all HiGain 
loopbacks and to display DS-1 line parameters and line unit identity.

Status LED

See 

Table 2

 for status descriptions.

Receive and transmit jacks

SPAN

Provides splitting jack access to (XMT) and from (RCV), the HDSL 
span at the DSX-1 interface. Breaks the XMT and RCV paths to 
permit test signal insertion and retrieval.

BRG

Provides non-intrusive bridging jack access to (XMT) and from 
(RCV), the HDSL span at the DSX-1 interface. Allows the two T1 
payloads to be monitored.

Craft (RS-232) port

Provides bidirectional communication between the unit and an 
external terminal to allow configuration and performance 
monitoring through the Maintenance terminal screens. 

CLEI and ECI bar code 
label

Provides the human-readable Common Language Equipment 
Identifier (CLEI) code number and the Equipment Catalog Item 
(ECI) bar code number.

List Number

Displays the version of the software that relates to the product.

Configuration Number

Contains either a five or six-digit warranty configuration number 
or a standalone two or three-digit configuration number as 
follows:

Digit 1 = Last digit of shipment year

Digits 2 and 3 = Shipment month

Digits 4, 5, and 6 = Configuration number

Table 2.

Status LED States

State

Description

Green

Normal Operation.

Flashing Green

HDSL Acquisition.

Flashing Red

Minor Alarm.

Red

FUSE ALRM.

Yellow

Self Test in progress or an HLU

-

431

 

List

 

1F

 loopback in effect 

(CREM) or (NLOC).

Flashing Yellow

The HLU

-

431

 

List

 

1F

 is in an ARMED (pre-loopback) state.

Содержание HLU-431

Страница 1: ...HIGAIN LINE UNIT QUICK INSTALLATION GUIDE PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES 350 431 116 01 SECTION 350 431 116 01 Model List Number Part Number HLU 431 1F 150 1504 16...

Страница 2: ...in this document is company private to PairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of PairGain Other product...

Страница 3: ...NSPECTING SHIPMENT Upon receipt of the equipment Visually inspect it for any signs of shipping damage Immediately report any damage to the shipping agent Check the packing list to ensure complete and...

Страница 4: ...SEL and Mode Front Panel Buttons 6 Default Settings 7 Using the Craft port 7 System Options Settings 9 Testing_________________________________________________12 Doubler Applications 12 Alarms 13 Loo...

Страница 5: ...two cable pairs For doubler applications one doubler may be used in the HDSL loops between the HLU 431 List 1F and the HRU Figure 1 on page 2 shows the front panel of the HLU 431 List 1F Table 2 on p...

Страница 6: ...HRE 450 Single slot outdoor HRE 454 Four slot outdoor HUE 443 three slot indoor PRODUCT DESCRIPTION Figure 1 shows the front panel of the HLU 431 List 1F and Table 2 on page 3 describes the various f...

Страница 7: ...T1 payloads to be monitored Craft RS 232 port Provides bidirectional communication between the unit and an external terminal to allow configuration and performance monitoring through the Maintenance...

Страница 8: ...Product Overview 350 431 116 01 Revision 01 4 January 8 1999 HLU 431 List 1F Figure 2 shows the card edge connector pinouts Figure 2 Card edge Connector Pinouts...

Страница 9: ...nto a shelf 1 Slide the unit into the shelf card guides for the desired slot 2 Push the unit in until it touches the backplane card edge connector and the retaining latch on the front panel opens 3 Pl...

Страница 10: ...hen HiGain is the transport system between utility company power substations which must be isolated from the cable pair to avoid damage from Ground Potential Rise GPR faults PROVISIONING The HLU 431 L...

Страница 11: ...the DFLT NO message appears 2 Press the SEL button again DFLT YES displays indicating the factory default values are now in effect To terminate the DFLT mode without setting the factory default values...

Страница 12: ...ter to be changed Each entry of this letter scrolls the parameter to its next value After all selections have been made press to exit and to confirm the changes This activates the new choices and retu...

Страница 13: ...rors on either HDSL loop or a total of 17 BPVs and FERR occur within a 24 hour period 170 Activates the alarm input signal to the LITESPAN microprocessor and flashes the red STATUS LED when 170 ES 170...

Страница 14: ...iGain system to respond to the Teltrend addressable repeater in band loopback codes A3LB Configures the HiGain system to respond to the Wescom addressable repeater in band loopback codes A4LB Configur...

Страница 15: ...signal at both the HLU and HRU T1 output ports when both of the HDSL loops are not in sync LOSW 1LP Causes HiGain to transmit the AIS signal at both the HLU and HRU T1 output ports when either of the...

Страница 16: ...on for 5 minutes if neither the MODE or SEL buttons are pressed The use of either button activates the four character display and restarts the 5 minute power control timer DOUBLER APPLICATIONS The lo...

Страница 17: ...r 2 has lost sync H1ES or H2ES HDSL Loop 1 or 2 Errored Second Loop 1 or 2 CRCs have exceeded the user selected ES threshold DS1 Digital Service 1 DS1 input BPVs at the HRU have exceeded the user sele...

Страница 18: ...ted by upstream in band codes or from the maintenance terminal CLOC Customer Local Loopback Loopback at HRU local toward CI initiated from CPE customer by in band codes or from the maintenance termina...

Страница 19: ...350 431 116 01 Revision 01 Testing HLU 431 List 1F January 8 1999 15 Figure 4 Loopback Functions...

Страница 20: ...establish synchronization over each of Loops 1 or 2 of Span 1 A2L1 or 2 a Acquisition 2 Loop 1 or Loop 2 The first HDU and the HRU multiplexers are trying to establish synchronization with each other...

Страница 21: ...esponse from HRU The HLU does not receive any response from the HRU Thus the HRU s integrity is questionable VER HLU Software Version Displays during the System Settings review mode Depress the MODE b...

Страница 22: ...utility substation or on a high voltage tower The maximum input voltage that the dc to dc converter can tolerate is 150V which makes it compatible with the HLU 431 List 1F whose maximum output voltage...

Страница 23: ...9 19 APPENDIX A SPECIFICATIONS Maximum Power Consumption 14W without doubler 18W with doubler Maximum Heat Dissipation 6W without doubler 7W with doubler Mounting 400 mechanics Dimensions Height 5 6 i...

Страница 24: ...r technical assistance is handled by an on duty Customer Service Engineer through a callback process This process normally results in a callback within 30 minutes of initiating the request BBS In addi...

Страница 25: ...airGain Customer Service to ask for a Return Material Authorization RMA number and any additional instructions Use the telephone or fax number listed below Telephone 800 370 9670 Fax 714 730 2961 3 In...

Страница 26: ...umber you received from Customer Service clearly on the outside of the carton PairGain Technologies Inc 14352 Franklin Ave Tustin CA 92780 7013 Attention CRF RMA Number If the equipment is defective p...

Страница 27: ...nal CLEI Common Language Equipment Interface LOSW Loss of Sync Word CO Central Office MAL Margin Alarm COM Communications MNGD Managed CPE Customer Premises Equipment NVRAM Non volatile Random Access...

Страница 28: ......

Страница 29: ...unit without cost during this period if the unit is found to be defective for any reason other than abuse or incorrect use or installation Do not try to repair the unit If it fails replace it with an...

Страница 30: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031...

Отзывы: