350-431-116-01, Revision 01
Provisioning
HLU-431 List 1F
January 8, 1999
7
3
Press the MODE button to select the desired parameter and move to the
next parameter. After you have configured the last parameter, the
display prompts you to confirm the settings.
4
Do one of the following:
•
Press the SEL button to install the settings.
•
Press the MODE button to bypass the settings.
If neither button is pressed in 30 seconds, the settings are bypassed.
D
EFAULT
S
ETTINGS
To return the system options back to the original factory default settings:
1
Press the SEL button until the DFLT NO message appears.
2
Press the SEL button again. DFLT YES displays indicating the factory
default values are now in effect.
To terminate the DFLT mode without setting the factory default values, press
the MODE button or do nothing for 30 seconds.
U
SING
THE
C
RAFT
PORT
The Craft port, a 9-pin RS-232 connector, on the HLU-
431
front panel allows
you to use a standard RS-232 cable to connect your system to a maintenance
terminal or PC running a terminal emulation program. Once connected you
can access the maintenance, provisioning, and performance screens.
To provision the HLU-
431
through the Craft port:
1
Configure the maintenance terminal to the following communication
settings:
•
1200 to 9600 baud (9600 baud is recommended)
•
Parity: NONE
•
8 data bits
•
1 stop bit