![PairGain HiGain SOLITAIRE H2TU-C-319 List 1 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/pairgain/higain-solitaire-h2tu-c-319-list-1/higain-solitaire-h2tu-c-319-list-1_technical-practice_3303800030.webp)
Provisioning
152-319-100-02, Revision 02
22
April 21, 2000
H2TU-C-319 List 1 and List 1C
DS1 BER (DBER) Option.
The DS1 BER alarm occurs when any of the DS1 or DSX-1 performance
monitoring parameters listed in
exceed the counts shown for the 24-hour period between 12:00:00 AM
through 11:59:59 PM. These thresholds correspond to a 10
-6
BER. All PM counters clear to zero at 12:00:00 AM
or when Master Clear is selected.
Resetting the H2TU-C
To reset the H2TU-C-319 to its original factory defaults:
1
Press
to select the Config menu.
2
Use the
and
arrow keys to select Set Factory Defaults, then press
.
3
Press
if you are certain you want to reset the H2TU-C, or press
to cancel this action.
Figure 10.
Configuration Menu - Reset to Factory Defaults
Table 7.
DS1/DSX-1 24-hour PM Threshold
Parameter
Threshold Count
CV-L (BPV)
133,400
ES-L, ES-P, PRM-NE, PRM-FE
648
SES-L, SES-P
100
UAS-P, UAS-L
10
Resetting the H2TU-C to its original factory settings may cause interruption of service.
C
↑↑↑↑
↓↓↓↓
ENTER
Y
N
Monitor
Performance
Event Log
Config
Inventory
Rlogon
Help
+----------------------+
| Standard Options ->
|
| PairGain Options ->
|
| Date and Time
->
|
| Master Clear
|
|
Set Factory Defaults
|
+----------------------+
SETTING FACTORY DEFAULTS...SERVICE *MAY* BE INTERRUPTED! ARE YOU SURE (Y/N)?
ID: xxxx--xxxx--xxxx--xxxx
04/21/00 12:30:01
H2TU-C
System: OK