Viewing Status
700-814-112-01, Revision 01
18
November 24, 1999
UTU-814 List 1B
V
IEWING
S
TATUS
View status using a maintenance terminal or PC running a terminal emulation
program connected to the line unit’s V.24 (RS-232) console port.
M
AIN
C
ONSOLE
S
CREEN
The main console screen displays a summary of LTU and NTU circuit
configuration, as well as performance statistics and alarm status for each
interface.
lists the information displayed in each field of the main
console screen.
Table 6.
Information Displayed in Main Console Screen
Field
Description
Circuit Configuration
DSX-1
Identifies the LTU and NTU DSX-1 port.
n
TS
Indicates the number of T1 time slots (
n
) selected for the DSX-1
application interface.
Nx64k
Identifies the LTU and NTU Nx64k serial data port.
n
k
Indicates the data rate selected for the Nx64k application interface.
RPF/WETTING
Indicates RPF (POWER) or WETTING mode for Remote Power Feed.
Nothing is shown when NONE is selected.
Timing
Indicates the clock source for the HDSL transmit direction.
EXT
External 1.544 MHz clock.
DSX-1
Clock extracted from T1 data stream.
Framing
Indicates the Framing Mode selected for the DSX-1 port.
D4-SF
Superframe contains 12 frames with 24 time slots per frame.
ESF
Superframe contains 24 frames with 24 time slots per frame.
Application Mode
Indicates application mode selected.
STRUCT
Structured with framing.
UNSTRUCT
Unstructured, no framing.
TSP
Time slot prioritization with framing.
SINGLE
Single pair with framing.