HDSL Span 1 Alarm History Screens
At the History HDSL Span 1 menu (
), type
to select the Alarm History status screen for HDSL
Span 1 (
Figure 43.
Alarm History Status Screen for HDSL Span 1
describes the four columns of data contained in each HDSL Span Alarm History screen.
If no alarm has occurred since the last alarms were cleared, the message "No alarms reported" displays on the
appropriate line for each alarm.
Table 26.
HDSL Span Alarm History Data
Column
Description
Alarm
Type of alarm: MAR1 (Margin Span 1), ES1 (Errored Seconds Span 1), LOSW1 (Loss
of Sync Word Span 1), PFO1
(a)
(Power Feed Open Span 1), PFS1
(a)
(Power Feed Short
Span 1).
First
Date and time the alarm first occurred.
Last
Date and time the alarm last occurred.
Count
Number of times the alarm has occurred since the alarms were last cleared.
(a)
Not supported. These units do not supply power to other units.
$