System Configuration
700-712-100-01, Revision 01
42
May 10, 1999
UTU-712 and ETU-762 List 1
3
Do one of the following:
•
Type
to keep the current settings.
•
Type
to reset values to factory defaults. The system resets and both LTU and NTU units go through
their respective synchronization processes. If loops are down or are in update mode while Set to Factory
Dflts is enabled, only the local unit will restart. If the loops are up, both the LTU and NTU will restart.
The factory default system settings are listed in
L
OGGING
O
FF
If the maintenance terminal must be left unattended for any length of time, log off until work resumes. This
prevents unauthorized persons from inadvertently changing operating parameters.
Log off by choosing Quit from the menu bar or by disconnecting the cable connecting the maintenance terminal
to the line or desktop unit. Automatic log off occurs after 20 minutes of keyboard inactivity.
Table 20.
Factory Default System Settings
Operating Option
Default Setting
System Settings
Application Mode
SINGLE
HDSL Rate Mode
MANUAL
HDSL Payload Rate
256kbps/4
Remote Console Access
ALLOWED
Protect Switch Command
Not supported on these units.
Local Unit Role
NTU
LTU/NTU Interface
Nx64k port
Interface Type
V.36
Data Rate/# of TSs
0
Beginning TS
0
Transmit Clock
INT-RISING (Internal Rising)
CTS
STD (Standard)
DSR
STD (Standard)
RLSD
STD (Standard)
LL/RR
ENA (Enabled)
Alarms LTU/NTU Interface
Loss of Clock (LOC)
MIN (Minor)
Alarms HDSL Spans
Margin (MAR)
MIN (Minor)
Margin Threshold
6
Errored Seconds (ES)
MIN (Minor)
24 Hour ES Threshold
70
Loss of Sync Word (LOSW)
MAJ (Major)
Power Feed Open (PFO)
Not supported on these units.
Power Feed Short (PFS)
Not supported on these units.
1
<