700-712-100-01, Revision 01
Installation and Startup
UTU-712 and ETU-762 List 1
May 10, 1999
21
ETU-762 D
ESKTOP
U
NIT
I
NSTALLATION
Perform the following steps to install an ETU-762 desktop unit.
1
Insert the AC power cord into the power cord receptacle on the ETU rear panel.
2
Plug the power cord into a source of 100 to 240 volt, 50 or 60 Hz AC power.
3
If configuring the desktop unit as an LTU, power up the shelf and proceed as instructed on pages
through
to access the Local Unit Role option in the Config System Settings menu (the default setting is
NTU).
4
Connect the data port cable from the DTE to the data port connector on the ETU-762 rear panel.
5
Connect the HDSL line cable to the HDSL line connector on the ETU rear panel.
6
Set the TT clock at the DTE for the default HDSL payload rate of 256 kbps (4 time slots).
HDSL S
TARTUP
AND
S
YNCHRONIZATION
The rate selectable LTU holds the configuration settings for the rate selectable NTU. At startup, the LTU first
confirms that the NTU is a rate selectable unit. The LTU then configures the NTU with the required settings.
Power up the rate selectable units and observe the synchronization process as follows:
1
Power up the shelf or enclosure where the unit(s) are installed.
2
Confirm the following:
•
The HDSL ALM LED is on and the HDSL SYNC LED flashes once per second as the units
self-configure and establish synchronization.
•
After approximately 60 seconds the HDSL ALM LED is off and the HDSL SYNC LED is a steady green.
The units are now ready for configuration through the console screen menus.
The line and desktop units will reset and their LEDs will sequence through the startup cycle
following any change to the Local Unit Role option. If necessary, log on again by pressing the
several times.
If the HDSL SYNC LED continues to flash after 90 seconds, the HDSL line is faulty or one of the
units is not a rate selectable unit. Check for the correct line units. Test the HDSL line using the
loopbacks described in
. Front panel loopback (LPBK) LED indications are
described in
.
The LTU and NTU will reset and the LEDs will cycle following any change to the HDSL Payload
Rate option (see
“Configure System Settings” on page 34