Specifications
700-712-100-01, Revision 01
10
May 10, 1999
UTU-712 and ETU-762 List 1
Alarms
Can be individually set to Disabled, Minor, or Major (major alarms actuate the UTU-712 alarm relay)
Serial Dataport Interface
Loss of Clock (LOC)
External Clock
Loss of Clock (LOC)
HDSL
Margin, programmable threshold (MAR)
Errored Seconds, programmable threshold (ES)
Loss of Sync Word (LOSW)
History
HDSL Interface
24-Hour (15-minute intervals) and 7-Day (24-hour intervals) for
ES and Unavailable Seconds (UAS)
Alarm
Time stamp of first and last occurrence, number of occurrences for
all enabled alarms
Power Requirements
UTU-712
Local input voltage
-36 Vdc to -72 Vdc
Consumption (typical)
6 W
ETU-762
Local input voltage
100 to 240 volt, 50 or 60 Hz, AC power
Consumption (typical)
6 W
Environmental
Operating Temperature Range
0
°
C to +50
°
C
Humidity
Up to 95% non-condensing
Storage Temperature
-40
°
C to +70
°
C
Storage Humidity
5% to 95% non-condensing
Regulatory Approvals
Safety
EN 41003, EN 60950
EMC/EMI
EN 55022, EN 50082-1 (IEC 801-2/3/4), EN 61000-3-2