150-458-100-05
Appendix B - Technical Reference
HRE-458 List 1, List 1B, and List 2
February 23, 2000
29
The HRE-458 can be used to house either HiGain doublers, ISDN, DDS, or 239 repeaters.
The wiring information shown in
has been made into a gummed label (
),
that is attached to the inside of the stainless steel dome for easy reference.
HRE-458 M
AINTENANCE
This section covers various maintenance procedures for the HRE-458.
Splicing
Splicing consists of connecting the wire pairs of the HRE-458 cable stub to the main cable located in the splice
case. The following sections contain step-by-step procedures for:
•
Preparing the stubs for splicing into the main cable (pre-splice procedure)
•
Splicing the stubs into the main cable (splicing procedure)
•
Dressing and taping the final splice in the splice case (post-splicing procedure)
Figure 12.
Cable Stub Construction
When using these splicing procedures, be sure to maintain cable pair integrity when splicing stub pairs into the
main cable. Follow local practices as required.
Pre-splicing Procedure
Ground the HRE-458 enclosure before splicing the cable stubs into the main cable. The
grounding method discussed in
(or an accepted local grounding
method) must be in effect at all times to safeguard personnel.
The HRE-458 comes with a screened cable stub that is precut and capped.
Содержание 150-458-100-05
Страница 4: ...Inspecting Shipment 150 458 100 05 iv February 23 2000 HRE 458 List 1 List 1B and List 2...
Страница 13: ...150 458 100 05 Overview HRE 458 List 1 List 1B and List 2 February 23 2000 5 Figure 3 Metal Valves...
Страница 49: ...150 458 100 05 Appendix D Glossary HRE 458 List 1 List 1B and List 2 February 23 2000 41...
Страница 50: ......