System Configuration
350-819-200-01, Revision 01
18
November 12, 1999
HLU-819 List 1
S
YSTEM
S
ETTINGS
The settings available in the Config System Settings menu are listed in
. The settings in boldface type are factory default settings.
Table 4.
Settings in Config System Settings Menu
System Setting
Description
Application mode
Select one of the following application modes:
UNSTRUCT
System operates in the unstructured (unframed) application mode
using 24 time slots. Use when LTU and NTU use either the DSX-1 or
Nx64K port with no framing. Two port (DSX-1 and Nx64K) operation
is not possible.
STRUCT
System operates in the structured (framed) application mode using
1 to 24 time slots. Use to transport framed voice channels between the
LTU and NTU DSX-1 ports and serial data between the Nx64K ports at
the same time.
TSP
System operates in time slot prioritization mode. Time slots 1 through
12 transport high priority traffic over Loop 1; time slots 13 through 24
transport low priority traffic over Loop 2. If a loop fails, time slots 1
through 12 are sent over the active loop. The NTU must be locally
powered. Remote Power Feed must be set to NONE.
SINGLE
System operates in single-pair mode using time slots 1 through 12 on
Loop 1. Use to transport framed voice channels between the LTU and
NTU DSX-1 ports or serial data between the Nx64K ports. The NTU
must be locally powered. Remote Power Feed must be set to NONE.
Remote Power
Feed Mode
Select one of the following power feed modes:
NONE
Disables the remote power feed mode. The NTU must be locally
powered. Used for TSP and SINGLE application modes.
POWER
LTU (HLU-819) supplies full power to the NTU through both loops.
WETTING
LTU (HLU-819) supplies a low level DC current to prevent corrosion
of HDSL lines and connections. The NTU must be locally powered.