350-819-200-01, Revision 01
Installation
HLU-819 List 1
November 12, 1999
9
5
Connect the Nx64K data port cable DB-25F (
), if applicable.
The following adapters can be used when connecting the cable:
•
ECA-800 List 1 (DB-25M to M-34F, V.35)
•
ECA-801 List 1 (DB-25M to DB-15F, X.21)
•
ECA-807, List 1 (DB-25M to DB-37F, RS-449, V.36)
6
Connect the HDSL line port cable DB-9F (
). The following
adapter can be used when connecting the cable:
•
ECA-806, List 1 (DB-15M to RJ-48C)
The UTU-814 is automatically configured as an NTU, which displays on
the maintenance terminal console screens after HDSL startup and
synchronization.
Figure 6.
ERE-811 List 2 Rear Panel
Jumpers and BNC are not applicable for UTU-814 List 1B. For
T1 applications, UTU-814 List 1B uses the standard 100
Ω
(DB-15), G.703 interface.
HDSL line (DB-9F)
Data port (DB-25F)
75 Ohm G.703
in (BNC)
75 Ohm G.703
out (BNC)
120 Ohm G.703 (DB-15F)
100-240v ~
50-60Hz 0.3A
Power cord
connector
DATA PORT
120 OHM / ALARM
HDSL LINE
75 OHM
IN
OUT
120 / 75 OHM JUMPER
SELECTION REQUIRED
ON LTU / NTU
-48V
RTN
-36V...-72V