150-431-115-01, Revision 01
Installation
HLU-431 List 1E
September 22, 1998
9
System Alarm Relay Output
The normally open alarm contacts available across pins 20 and 21 (
) comprise the HLU-231
system alarm output. These alarm contacts close for any system alarms condition. This alarm contacts also close
if power is lost or removed from the slot, providing fail-safe relay output. See
for
further information about system alarms.
I
NSTALLATION
To install the HLU-431:
1
Slide the HLU-431 into the card guides for the desired slot, then push the unit back until it touches the
backplane card-edge connector and the retaining latch on the front panel opens (
Figure 3.
Installing the HLU-431 into a Shelf
2
Place your thumbs on the HLU-431 front panel and push the HLU-431 into the card-edge connector until it
is entirely within the card guides and the retaining latch closes. This indicates that the card is properly seated.
HLU-431
CO Shelf
PairGain
HL
U-
431
HiGa
in L
INE UNI
T