![PairGain 150-1217-03 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/pairgain/150-1217-03/150-1217-03_manual_747319009.webp)
Section 150-611-103
Revision 01
Page 9
9.03
GNLB is the HiGain-2 Generic loopback
code. The GNLB allows 4 in 7 or 6 in 7 in-
band codes to loop-up the HLU (NLOC or CREM
respectively) and 3 in 7 or 4 in 7 in-band codes to
loop-up the HRU (NREM or CLOC respectively).
NLOC & NREM are issued from the HLU DS1
interface. CLOC & CREM are issued from the HRU
DS1 interface. All looped states are terminated
(looped-down) with the 3 in 5 loop-down code. All
commands must be present for 5 seconds before
HiGain-2 responds. Table 3 lists the test
procedures that apply when using the GNLB mode.