150-451-103-02, Revision 02
Monitoring the HDSL System
HDU-451 List 3
September 18, 1998
23
Figure 8.
System Settings Screen
To exit this screen and return to the Main Menu, type
, then press
.
describes the fields of the System Settings screen.
Table 9.
System Settings Screen Fields
Field
Description
Time
Time of day when System Settings were checked.
Date
Date when System Settings were checked.
Equalization
Indicates settings for equalizer of either EX1, 0 (DSX-1 for 0-133 ft),
133 (DSX-1 for 133-266 ft), 266 (DSX-1 for 266-399 ft),
399 (DSX-1 399-533 ft), 533 DSX-1 for 533-655 ft).
Smart-Jack LB
Indicates settings of either
ENA
or
DIS
for SmartJack loopback: where
signal from DS1 is looped back at the HRU to the DSX-1.
Special LBPK
Indicates the special loopback settings of either: Generic loopback
(GNLB), where the HiGain system responds to the generic in-band
loopback codes, or A1LB and A2LB, A3LB, A4LB, or A5LB.
Power
Indicates whether power feed to the HRU-402 from the HLU is either
OFF, AUTO, HIGH, or LOW.
SYSTEM SETTINGS
TIME: 00:30:50
DATE: 01/07/97
CIRCUIT ID#: -- P --
EQUALIZATION:
EX1
SMART-JACK LB:
ENABLE
SPECIAL LPBK:
GNLB
POWER:
ENABLE
ZBTSI:
OFF
ES ALARM THRES:
NONE
LOOPBACK TIMEOUT: 60
ALARM:
DISABLE
DS1 CODE:
AUTO
FRAMING:
AUTO
AIS ON HDSL LOSW: 2 LOOPS
AIS ON SMJK/NREM: ENABLE
MARGIN ALM THRES: 4
DS0 BLOCKING: xx - Blocked Channels
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
(E)xit
Содержание 150-1143-03
Страница 4: ...Using This Manual 150 451 103 02 Revision 02 iv September 18 1998 HDU 451 List 3...
Страница 39: ...150 451 103 02 Revision 02 Pinouts HDU 451 List 3 September 18 1998 31 Figure 13 HDU 451 DB 9 Pin Outs...
Страница 46: ...Product Support 150 451 103 02 Revision 02 38 September 18 1998 HDU 451 List 3...
Страница 47: ...150 451 103 02 Revision 02 Product Support HDU 451 List 3 September 18 1998 39...