Provisioning
150-388-105-05, Revision 05
18
March 25, 2000
HLU-388 List 5
Span Status Screen for Doubler Applications
If doublers have been added, status is also reported for these, as shown in
. Span Status can have up to
five screens, depending on the number of HDUs.
Figure 6.
Span Status Screen for Doubler Applications
SPAN 5 STATUS
TIME: 12:06:04
DATE: 02/18/00
Circuit ID#:
ALARMS:
NONE
LOOPBACK: OFF
POWER LEVEL: HIGH
HDU4
HRU
HDSL-1
HDSL-2
HDSL-1
HDSL-2
cur/min/max
cur/min/max
cur/min/max
cur/min/max
MARGIN:
23/23/23
23/21/23
24/20/25
24/21/24
dB
PULSE ATTN:
07
07
07
07
dB
INS LOSS:
08
08
08
08
dB
24 HOUR ES:
00010
00008
00001
00002
seconds
24 HOUR UAS:
00021
00020
00004
00002
seconds
DS1 STATUS
HLU
HRU
24 HOUR ES Count:
00000
00017
24 HOUR UAS Count:
00000
00012
Frame type:
ESF
ESF
Code type:
AMI
AMI
AUTOUPDATE OFF
(E)xit (C)lear (A)uto(U)pdate (S)pan(1)(2)(3)(4)(5)