Maintenance
150-231-175-01, Revision 01
14
September 23, 1998
HLU-231 List 7E
M
AINTENANCE
T
ERMINAL
M
AIN
M
ENU
shows the Maintenance Terminal Main Menu from which you can access eight system administration
screens. The function of each screen selection is listed in
Figure 6.
Maintenance Terminal Main Menu
Table 6.
Maintenance Terminal Screens
Screen
Function
See page:
View Span Status
Provides access to subscreens that allow you to monitor the HDSL
line between the HLU and the HRU.
Set Clock
Allows you to set both the time and the date parameters at the HLU,
and to update the same settings at the HRU.
System Settings
Allows you to set all user options.
Loopback Mode
Provides access to subscreens that allow you to issue and disable
loopbacks at all circuit module locations.
View Performance Data
Provides access to subscreens that allow you to view the Errored
Seconds (ES) and Unavailable Seconds (UAS) between the HLU and
the HRU in 15-minute intervals over a 4-hour time period.
View Performance History
Provides access to subscreens that allow you to view the ES and UAS
between the HLU and the HRU in 24-hour intervals over a 7-day
period.
View Alarm History
Provides access to subscreens that allow you to view alarm
conditions between the HLU and the HRU.
Enter Circuit ID #
Allows you to enter a unique circuit ID (up to 24 characters).
HI-GAIN HLU-231 MAINTENANCE TERMINAL MAIN MENU (ver V5.4L-7E)
CIRCUIT ID#:
A. VIEW SPAN STATUS
B. SET CLOCK
C. SYSTEM SETTINGS
D. LOOPBACK MODE: NONE
E. VIEW PERFORMANCE DATA
F. VIEW PERFORMANCE HISTORY
G. VIEW ALARM HISTORY
H. ENTER CIRCUIT ID #