Electric heater Aqua spa

ENGLISH

Electric installations

Electric installation may be performed only by a qualified electrician.

Electric heater must be connected electrically to phase, neutral and protective earth conductors.
Electric installation must be done via an all-pole work switch and ground fault switch indirectly via contactor controlled from  
the pool pump electric connections. This is because the heater cannot be started without the water circulating in the pool.

Diagram

Felsökning

For safety reasons, the heater’s overheat protection will dissolve in case of lack of water or poor circulation. This is the most 
common reason why the heater “stopped working”.

Find the cause of the lost overheating protection.
After the cause has been found and corrected, the overheating protection must be reset:
1.  Remove protective cover, see Fig. 1 below.
2.  Press the reset button on the junction box, see Fig. 2 below.
3.  Install protective cover again.

Protective cap

Protective cap

Reset button

Start

1.  Fill water into the pool up to the right level.
2.  Start the pool pump.
3.  The heater will start only when the system is emptied of all air.
4.  Set the desired pool temperature by turning the knob to the desired temperature.
5.  Water is now heated to the set temperature.

Operation

When flushing and cleaning the filter, turn off the power to the heater.

In case of freezing, switch off the power and drain the heater of all water.

Electric heater

Overheating 
protection

Thermostate

Flow  
switch

On/Off

1

~

230V