Electric heater Aqua spa
ENGLISH
Electric installations
Electric installation may be performed only by a qualified electrician.
Electric heater must be connected electrically to phase, neutral and protective earth conductors.
Electric installation must be done via an all-pole work switch and ground fault switch indirectly via contactor controlled from
the pool pump electric connections. This is because the heater cannot be started without the water circulating in the pool.
Diagram
Felsökning
For safety reasons, the heater’s overheat protection will dissolve in case of lack of water or poor circulation. This is the most
common reason why the heater “stopped working”.
Find the cause of the lost overheating protection.
After the cause has been found and corrected, the overheating protection must be reset:
1. Remove protective cover, see Fig. 1 below.
2. Press the reset button on the junction box, see Fig. 2 below.
3. Install protective cover again.
Protective cap
Protective cap
Reset button
Start
1. Fill water into the pool up to the right level.
2. Start the pool pump.
3. The heater will start only when the system is emptied of all air.
4. Set the desired pool temperature by turning the knob to the desired temperature.
5. Water is now heated to the set temperature.
Operation
When flushing and cleaning the filter, turn off the power to the heater.
In case of freezing, switch off the power and drain the heater of all water.
Electric heater
Overheating
protection
Thermostate
Flow
switch
On/Off
1
~
230V