6
2.3
Battery Connections:
Model 9702R:
4 x PAGlok connectors.
Model 9702VR: 4 x V-Mount connectors.
Model 9702AR: 4 x Gold Mount connectors.
2.4
Main Charge Program:
> Li-Ion Intelligent Parallel Charging program.
> Maximum output 6A at 16.8V (100W approx.).
2.5
Recovery Charge Program:
This special program will automatically recover a Li-Ion battery where the
output has been shut down. Additionally, the program detects batteries having
a very low voltage, and initiates a special low charge current. The program will
operate until the voltage has risen sufficiently for batteries to safely accept the
normal charge current.
2.6
Self Test Program:
The internal microcomputer constantly monitors the battery under charge or
process as well as the operation of the charger’s own functions which will be
shut down to a safe condition should any of the tests fail.
2.7
Mains Input:
90V to 265V AC. Frequency 50-60 Hz. EN6100-3-2 Power factor corrected.
Maximum consumption 140W.
2.8
Output Protection:
Charger protected against short circuit and excess battery voltage.
2.9
AC Mains Failure Protection:
Should mains failure occur during a charging program, or whilst the charger is
connected, it will shut down to a safe condition.
2.10 User Interface:
Comprehensive Liquid Crystal Display showing status of battery and charger. The
charger is fully automatic in operation and no user controls are provided.
2.11 Safety:
Designed to comply with electrical safety standard BS EN 60065 and UL1564.
NOTE: UK mains leads are fitted with a 1" fuse to BS1362 rated 5A as standard.
2.12 European Union Directives:
Complies with the following EU Directives:
> EMC Directive 89/336/EU.
> Low Voltage Directive 73/23/EU.