OPERATING INSTRUCTIONS
SECTION 4
4.1
IMPORTANT: Note section 4.16 Supply Failure. PAGlink PL16+ Chargers may be
disconnected from the supply at any time in complete safety and without
damage to the charger or any batteries connected.
4.2
Connect the charger to a suitable supply using the standard lead. The red LCD
screen will illuminate.
4.3
On power-up, the charger will automatically run a self test program. With no
batteries connected, the display will indicate ‘ABST’ on all four channels.
4.4
When batteries are connected, charging will automatically commence
and the charger display will indicate ‘CHRG’ on the appropriate channels.
4.5
Li-Ion batteries are charged simultaneously, using PAG’s Intelligent Parallel
Charging program (see ‘Typical Battery Charging Times’ Section 2.16).
NOTE: Older generation PAG Li-Ion batteries will be charged sequentially.
4.6
Up to 8 PAGlink batteries per channel may be charged. Batteries can be in
any state-of-charge. The most-discharged batteries will be given a higher
charge priority. The charge status of each PAGlink battery is indicated by its
own display. Fully-charged batteries stop accepting charge automatically and
independently of other batteries.
4.7
The charger display will indicate ‘DONE’ when all the batteries connected to
that channel have received as much charge as they can safely accept.