3)Setting operation
Mode code
Function
Operation step
1
F1
Set
℃
/
℉
scale
Press MODE button for 2 seconds, the screen
will display F1 on the bottom right, press UP or
DOWN button can change temperature unit
for
℃
or
℉
.
2
F2
Set alarm temp.
Press MODE button for 2 seconds, the screen
display F1, press MODE button to get F2,
select UP to increase the threshold by 0.1
℃
(0.1
℉
), DOWN to reduce it by
0.1
℃
(0.1
℉
). The
alarm threshold default value is
38.0
℃
(100.4
℉
).
3
F3
Set difference
Press MODE button for 2 seconds, the screen
display F1, press two times to get F3, select
UP to increase the difference by 0.1
℃
(0.1
℉
),
DOWN to reduce it by
0.1
℃
(0.1
℉
). In the case of
seasonal or environmental changes a verification and
adjustment should be carried out.
Note: This function is only effective body.
4
F4
Set buzzer on/off
Press MODE button for 2 seconds, the screen
display F1, press 3 times to get F4. Select UP
to turn on the buzzer, press DOWN to stop it.
- 9 -