paco MCD-500VA Скачать руководство пользователя страница 11

6 secs.  /  120 secs.

P/No.

Input 
Voltage

Output 
Voltage

Output 
Power

Frequency

Output 
Precision

High 
Voltage 
Protection

Low 
Voltage 
Protection

High 
Output 
Voltage 
Protection

Input 
Fuse

Fuse 
Size

Delay 
Time

Thermal 
Protection

Cooling
Fan

Dimension 
(L x W x H)

500VA

50/60Hz

+/-10%

Circuit Protection

Circuit Protection

255V~

250V AC,
T5.0A

5x20mm

O

130  C  +/-5%

No

24.5x11.3x16.5
cm

1000VA

1500VA

2000VA

3000VA

5000VA

250V AC,
T8.0A

250V AC,
T10A

250V AC,
T15A

16A  

25A

5x20mm

5x20mm

5x20mm

Circuit 
breaker

Circuit 
breaker

No

No

No

Yes Auto-operation fan 
(temperature or load)

26.3x12.5x17
cm

28.3x14x19
cm

39x21.5x26
cm

39x21.5x26
cm

220V

230V

240V               110V

115V

~              

~              

~              

16. SPECIFICATION

10

specification are subjected to change without prior notice.

100-260V~

120-260V

140-260V

              

~               

~                80-140V~

Overload 
Protection

Circuit Protection

MCD-5000VA

MCD-3000VA

MCD2000VA

MCD-1500VA

MCD-1000VA

MCD-500VA

28.3x14x19
cm

Содержание MCD-500VA

Страница 1: ...DELAYING WORKING DELAY UNDELAY AUTOMATIC VOLTAGE REGULATOR INPUT OUTPUT MICROPROCESSOR CONTROL CPU AUTOMATIC VOLTAGE REGULATOR Instruction Manual Please read user manual carefully before use HIGH LOW...

Страница 2: ...AGE REGULATOR INPUT OUTPUT Microprocessor Control CPU Wide Range Voltage Regulation Automatically Executes Protection When Protection Finished Goes Off High Voltage Protection Yes Low Voltage Protecti...

Страница 3: ...ut Output Front Panel 3000VA 5000VA Rear Panel 3000VA 5000VA FIG 3 MCD 5000VA UNUSUAL DELAYING WORKING DELAY UNDELAY AUTOMATIC VOLTAGE REGULATOR OFF ON INPUT OUTPUT 2 MCD 1000VA UNUSUAL DELAYING WORKI...

Страница 4: ...ve only after users notify manufacturer in advance WHEN OUTPUT VOLTAGE OF AVR IS HIGHER THAN SET VALUE THE SYSTEM ENTER INTO HIGH LOW VOLTAGE PROTECTION UNUSUAL RED LED FLASHES EVERY ONE SECOND AND OU...

Страница 5: ...ion This function should be effective only after users notify manufacturer in advance 5 LED DIGITAL DISPLAY INDICATOR ILLUSTRATION LED Digital Display Indicator Illustration CONDITION INPUT DISPLAY IN...

Страница 6: ...he unit Switch on appliance after you make sure the unit is working normally with output voltage When connecting the electrical appliance with motor or compressor such as drill air conditioner and so...

Страница 7: ...off automatically if the total wattage of the electrical appliances exceed the automatic voltage regulator output capacity 9 OVERLOAD PROTECTION When avr is overload the system will turn into self pro...

Страница 8: ...THE POWER CURVE OF OUTPUT USE THE SAME CURRENT FUSE FOR REPLACEMENT 100 120 140 160 180 200 220 240 260 280 300 P 100 75 50 25 U V OUTPUT 220V 7 FUSE Fuse Input Output On the rear panel of the automat...

Страница 9: ...automatically cut off the output In such cases A switch off the power at once B disconnect all units C check the connected devices D use the unit again unless the problems concerning the connected de...

Страница 10: ...any other heat source C Inaccessible to children D Safe from water moisture oil or grease E Safe from any flammable substance WARNING DO NOT DISASSEMBLE THE UNIT HAZARDOUS VOLTAGE DANGER PLEASE RETUR...

Страница 11: ...O 130 C 5 No 24 5x11 3x16 5 cm 1000VA 1500VA 2000VA 3000VA 5000VA 250V AC T8 0A 250V AC T10A 250V AC T15A 16A 25A 5x20mm 5x20mm 5x20mm Circuit breaker Circuit breaker No No No Yes Auto operation fan t...

Страница 12: ...ut power of the regulator For color TV calculate it twice as its listed capacity Make sure that the regulator is of the same output voltage and frequency as the appliance s it connected Make sure that...

Отзывы: