7.  LOW & HIGH VOLTAGE PROTECTION

When output voltage is lower or higher than labeled voltage, AVR will turn 
into self-protection state automatically ,the UNUSUAL RED indicator 
flashes every one second and output voltage will be cut off.

When output voltage comply with labeled voltage, AVR will go into 
automatic recovering state, the UNUSUAL RED indicator extinguishes. 
Then DELAYING ORANGE indicator flashes every one second, the 
system goes into delaying state. After delay, DELAYING ORANGE 
indicator extinguishes and output voltage resume .

10. WITH COOLING FAN

When the temperature of transformer excessed 90

+/-5%, the cooling 

fan will switch on automatically to low down inside temperature and will 
stop working while the temperature comes down.

NOTE: 

This function only suitable for 3KVA , 5KVA

11. OUTPUT CAPACITY

The automatic voltage regulator will switch off automatically if the total 
wattage of the electrical appliances exceed the automatic voltage 
regulator output capacity. 

9.OVERLOAD PROTECTION

When avr is overload, the system will turn into self-protection, red led 
indicator will illuminate continuously and there is no output.  To resume 
the output, you should lessen the load and then restar the unit.

NOTE:

 This function only suitable for 3KVA / 5KVA

NOTE: 

No overload Protection is equipped in standard configuration, 

users should notify manufacturer and take special order if this function 
is required.

8. THERMAL PROTECTION

NOTE:

 No overheating Protection is equipped in standard configuration, 

users should notify manufacturer and take special order if this function 
is required.

When the temperature of the transformer exceeds 130

+/-5% , the 

system will automatically turn into self-protection state, UNUSUAL RED 
indicator will flash every one second and output voltage shut down. While 
temperature is lower 70

+/-5% , the system will recover automatically. 

UNUSUAL RED indicator will extinguish, and output resume.

Содержание MCD-1000VA

Страница 1: ... DELAYING WORKING DELAY UNDELAY AUTOMATIC VOLTAGE REGULATOR INPUT OUTPUT MICROPROCESSOR CONTROL CPU AUTOMATIC VOLTAGE REGULATOR Instruction Manual Please read user manual carefully before use HIGH LOW VOLTAGE PROTECTION ...

Страница 2: ...TAGE REGULATOR INPUT OUTPUT Microprocessor Control CPU Wide Range Voltage Regulation Automatically Executes Protection When Protection Finished Goes Off High Voltage Protection Yes Low Voltage Protection Yes Overload Protection Yes 3KVA 5KVA High Temperature Protection Yes Circuit Protection Circuit Breaker Smart Cooling System Yes 3KVA 5KVA 1 FEATURES 2 DESCRIPTION FIG 1 Rear Panel 300VA 500VA Fu...

Страница 3: ...put Output Front Panel 3000VA 5000VA Rear Panel 3000VA 5000VA FIG 3 MCD 5000VA UNUSUAL DELAYING WORKING DELAY UNDELAY AUTOMATIC VOLTAGE REGULATOR OFF ON INPUT OUTPUT 2 MCD 1000VA UNUSUAL DELAYING WORKING DELAY UNDELAY AUTOMATIC VOLTAGE REGULATOR INPUT OUTPUT OUTPUT VOLTAGE METER INPUT VOLTAGE METER DELAYING INDICATOR WORKING INDICATOR UNUSUAL INDICATOR DELAY UNDELAY SELECTOR POWER SWITCH Output ...

Страница 4: ...ive only after users notify manufacturer in advance WHEN OUTPUT VOLTAGE OF AVR IS HIGHER THAN SET VALUE THE SYSTEM ENTER INTO HIGH LOW VOLTAGE PROTECTION UNUSUAL RED LED FLASHES EVERY ONE SECOND AND OUTPUT GOES OFF WHEN OUTPUT VOLTAGE OF AVR IS UNDER SET VALUE THE SYSTEM ENTER NORMAL WORKING STATE UNUSUAL RED LED EXTINGUISHES WHEN TEMPERATURE OF AVR IS HIGHER THAN SET TEMPERATURE THE SYSTEM ENTER ...

Страница 5: ...tion This function should be effective only after users notify manufacturer in advance 5 LED DIGITAL DISPLAY INDICATOR ILLUSTRATION LED Digital Display Indicator Illustration CONDITION INPUT DISPLAY INDICATOR OUTPUT DISPLAY INDICATOR Power Off Extinguish Extinguish Working Input Voltage Output Voltage Delay state Voltage at low voltage protection selective Countdown selective Output high voltage p...

Страница 6: ...the unit Switch on appliance after you make sure the unit is working normally with output voltage When connecting the electrical appliance with motor or compressor such as drill air conditioner and so on to the automatic voltage regulator please make sure that the power rating of the automatic voltage regulator is at least 3 times of the power rating of the electrical appliance so that it can work...

Страница 7: ... off automatically if the total wattage of the electrical appliances exceed the automatic voltage regulator output capacity 9 OVERLOAD PROTECTION When avr is overload the system will turn into self protection red led indicator will illuminate continuously and there is no output To resume the output you should lessen the load and then restar the unit NOTE This function only suitable for 3KVA 5KVA N...

Страница 8: ... THE POWER CURVE OF OUTPUT USE THE SAME CURRENT FUSE FOR REPLACEMENT 100 120 140 160 180 200 220 240 260 280 300 P 100 75 50 25 U V OUTPUT 220V 7 FUSE Fuse Input Output On the rear panel of the automatic voltage regulator there is a terminal fitted with a nut This terminal is connected to the case of the automatic voltage regulator and also to the earth terminal of the AC output socket The use of ...

Страница 9: ...l automatically cut off the output In such cases A switch off the power at once B disconnect all units C check the connected devices D use the unit again unless the problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may suddenly be cut off although the input voltage normal This may be caused by excessive temperatures If this happens ...

Страница 10: ...r any other heat source C Inaccessible to children D Safe from water moisture oil or grease E Safe from any flammable substance WARNING DO NOT DISASSEMBLE THE UNIT HAZARDOUS VOLTAGE DANGER PLEASE RETURN TO THE DEALER IF YOU FIND ANY PROBLEM WITH THE UNIT 9 14 MAINTENANCE Very little maintenance is required to keep your automatic voltage regulator operating properly You should clean the exterior of...

Страница 11: ... O 130 C 5 No 24 5x11 3x16 5 cm 1000VA 1500VA 2000VA 3000VA 5000VA 250V AC T8 0A 250V AC T10A 250V AC T15A 16A 25A 5x20mm 5x20mm 5x20mm Circuit breaker Circuit breaker No No No Yes Auto operation fan temperature or load 26 3x12 5x17 cm 28 3x14x19 cm 39x21 5x26 cm 39x21 5x26 cm 220V 230V 240V 110V 115V 16 SPECIFICATION 10 specification are subjected to change without prior notice 100 260V 120 260V ...

Страница 12: ...put power of the regulator For color TV calculate it twice as its listed capacity Make sure that the regulator is of the same output voltage and frequency as the appliance s it connected Make sure that the voltage of electrical source is within the listed range of the input voltage of the regulator Always place the regulator in an environment that is A Well ventilated B Not exposed to direct sunli...

Отзывы: