75/78
06/02/2008
1.00
Specials
The DIB cooling system
The DIB cooling system
Together with the milk tank, the double-walled, stainless steel heat exchanger forms one unit. The supporting
plate is laser welded to the flat plate of the inner tank (the real milk tank) and expanded under pressure.
At the bottom of the milk cooling tank, the ice water is pumped into the heat exchanger through a multi
injection manifold. At the top, the warmed up ice water is extracted. In this way, the heat exchanger surface
is used for the full 100 %.
The various injection points are connected by stainless steel collector pipes. This is called the MULTI
injection system.
Schematic overview
The drawing below gives you a schematic overview of the DIB cooling system with pre-cooler:
Parts
Part
Function
1
Pre-cooler (optional)
2
Heat exchanger
3
Milk cooling tank
4
Ice-builder: ice + ice water
5
Ice water pump
Ice water
Warmed up ice water
Milk