Packeteer PacketSeeker 10000 Скачать руководство пользователя страница 6

Chapter 1: Introduction

1-2

Gigabit LAN Expansion Module Requirements

The software for the 

LEM2-1000M-T

 Gigabit LAN Expansion 

Module is included in PacketWise version 6.1.0 and all later 
versions. The Ro

H

s-compliant 

LEM2G-1000M-T 

requires 

PacketWise 7.x

 or later

.

Note: 

The PacketShaper 10000, PacketSeeker 10000 and 

PacketShaper/ISP 10000 are only compatible with LEM2G-
1000M-T and later-generation LEM2-1000M-T LAN 
Expansion Modules. These newer LEM2-1000M-T LEMs 
can be identified by their serial numbers, which have values 
of 006-

100

10001

 or higher.

 

For details, see “Problems?” on 

page 3-12.

LANs connected to this copper-connector LEM module must use 
10BaseT, 100BaseT, or 1000BaseT RJ-45 Ethernet ports or use 
fiber optic conversion units for fiber optic networks.

LED 
Indicators

The front panel of the LEM has the following LED indicators 
beside each port. 

LED 
Indicator

Description

Link

Illuminated when the network cable is 
properly connected

Tx/Rx

Illuminated when network cable is properly 
connected; flickers when the unit is 
transmitting and receiving data

Speed

When properly installed, the speed LED 
color on the LEM module

 

indicates that the 

LEM is operating at the following speeds:

• amber = 1GB
• green = 100MB 
• off  =  10MB

Содержание PacketSeeker 10000

Страница 1: ...00 GIGABIT LAN EXPANSION MODULE P N 20 0162 03 Rev B ...

Страница 2: ...ompany names used in this document are used for identification purposes only and may be trademarks of other companies and are the property of their respective owners Copyright 1996 2006 Packeteer Inc All rights reserved No part of this document may be reproduced photocopied stored on a retrieval system transmitted or translated into another language without the express written consent of Packeteer...

Страница 3: ... LEM 2 2 Verify the Installation 2 7 Configure the LEM module 2 8 Connect the Unit to a Router 2 9 Managing Traffic with Three LANs 2 12 Problems 2 13 Chapter 3 Install into a 8500 9500 10000 Model Installing the LEM 3 2 Verify the Installation 3 6 Configure the LEM module 3 7 Connect the Unit to a Router 3 8 Managing Traffic with Three LANs 3 11 Problems 3 12 Appendix A Safety and Regulatory Info...

Страница 4: ......

Страница 5: ...e LANs The following scenarios are examples of situations that require a Lan Expansion Module You want to manage a single WAN link and your network includes a firewall router that splits your network into two separate LANs a protected segment and a DMZ segment You want to manage a single WAN link and your network includes a router with multiple LAN segments You have a single WAN link and your netw...

Страница 6: ...ch have values of 006 10010001 or higher For details see Problems on page 3 12 LANs connected to this copper connector LEM module must use 10BaseT 100BaseT or 1000BaseT RJ 45 Ethernet ports or use fiber optic conversion units for fiber optic networks LED Indicators The front panel of the LEM has the following LED indicators beside each port LED Indicator Description Link Illuminated when the netwo...

Страница 7: ...a 6500 Model If your unit looks either one of these follow the installation directions in Chapter 3 Install into a 8500 9500 10000 Model FAULT POWER STATUS Tx Rx 100 LINK Tx Rx 100 OUTSIDE INSIDE LINK CONSOLE FAULT POWER STATUS CONSOLE INSIDE OUTSIDE LINK Tx Rx SPEED LINK Tx Rx SPEED FAULT POWER STATUS CONSOLE OUTSIDE INSIDE OUTSIDE LINK Tx Rx LINK Tx Rx FAULT POWER STATUS CONSOLE OUTSIDE INSIDE O...

Страница 8: ...Chapter 1 Introduction 1 4 ...

Страница 9: ...ch are hereafter collectively referred to as a 6500 model The following illustration shows a unit with two LEMs installed for a total of three LANs using one 6500 model This is a maximum configuration you can install only one module if you wish Directions begin on the next page FAULT POWER STATUS Tx Rx 100 LINK Tx Rx 100 OUTSIDE INSIDE LINK CONSOLE WAN Router INPUT 100 240 MAX 50 60Hz INSIDE OUTSI...

Страница 10: ...u open the system or do any procedures can result in personal injury or equipment damage 2 Ground yourself WARNING Electrostatic discharge ESD can damage system components If an ESD station is not available wear a wrist strap attached to a metal part of the system If you don t have a strap touch some metal part of the box to ground yourself 3 Remove the rackmount ears if present from the 6500 mode...

Страница 11: ...Chapter 2 Install into a 6500 Model 2 3 4 Remove the unit cover 5 Remove the screw that holds one of the slot covers in place To install two modules remove both slot covers INSIDE OUTSIDE ...

Страница 12: ...acket supplied with the LEM by aligning the screw holes on the bracket tabs directly above the screw holes on the module then inserting the screws from below WARNING Using an incorrect bracket can damage the module or the 6500 model SPEED Tx Rx LINK SPEED Tx Rx LINK OUTSIDE 10 100 1000MB Ethernet INSIDE SPEED Tx R x LIN K OUTSID E IN SID E SPEED Tx R x LIN K ...

Страница 13: ...hem if you later wish to disable the standby function For additional information on enabling or disabling standby refer to the latest Getting Started Guide for your Packeteer unit available at http support packeteer com documentation 9 Locate the expansion slots on the riser card in the interior of the 6500 model LINK Tx Rx SPEED Tx Rx LINK OUTSIDE 10 100 1000MB Ethernet INSIDE SPEED Tx Rx LINK OU...

Страница 14: ...rd so hard that it disconnects from the motherboard Note that there are extra pins on the LEM that are not used on a 6500 model These extra pins will not attach to the riser card 11 If you are installing two LEMs repeat steps 6 10 for the other module 12 Replace the screw s that holds the expansion card s in place then replace the cover and cover screws SPEED Tx R x LIN K SPEED Tx R x LIN K OUTSID...

Страница 15: ...ollowing NIC modes for each LEM interface 10BaseT half duplex 10BaseT full duplex 100BaseT half duplex 100BaseT full duplex 1000BaseT full duplex Auto negotiate is the default network communication selection Note Selecting 1000BaseT full duplex causes the unit to auto negotiate per IEEE standard The screen above indicates that the built in LEM card for this unit is 100 Megabits the lower slot cont...

Страница 16: ...de interface settings also apply to the LEM interfaces 3 You can change security settings for all Inside and Outside interface communication if desired Click the Inside Interfaces and Outside Interfaces drop down lists to set access to all none or specified devices Setting Access Level unsecure default Enables unlimited access over the specified interface secure Blocks all access from the specifie...

Страница 17: ...through cable connected to LAN A 2 Reconnect this cable to the built in port on the unit labeled INSIDE 3 Connect the unit s OUTSIDE port the router using the orange cross over cable FAULT POWER STATUS Tx Rx 100 LINK Tx Rx 100 OUTSIDE INSIDE LINK CONSOLE WAN Router INPUT 100 240 MAX 50 60Hz INSIDE OUTSIDE INSIDE OUTSIDE LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LAN A WAN ...

Страница 18: ...rt disconnect the straight through cable connected to LAN B 2 Reconnect this cable to the INSIDE port of the LEM 3 Using the orange cross over cable connect the OUTSIDE port to the router FAULT POWER STATUS Tx Rx 100 LINK Tx Rx 100 OUTSIDE INSIDE LINK CONSOLE WAN Router INPUT 100 240 MAX 50 60Hz INSIDE OUTSIDE WAN LAN A LAN B LINK Tx Rx SPEED LINK Tx Rx SPEED ...

Страница 19: ...N C 2 Reconnect this cable to the INSIDE port of the second LEM 3 Using the orange cross over cable connect the OUTSIDE port to the router LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED FAULT POWER STATUS Tx Rx 100 LINK Tx Rx 100 OUTSIDE INSIDE LINK CONSOLE WAN Router INPUT 100 240 MAX 50 60Hz INSIDE OUTSIDE OUTSIDE LAN C LAN A LAN B LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx R...

Страница 20: ...you would create a class for each subnet and put classes such as POP3 under each subnet class Note Even though traffic classes are combined each LAN s traffic is an individual flow 6500 models cannot route traffic between LANs For example if one LAN has public servers and the other does not the security of the non public LAN will not be compromised Traffic between LANs LAN A to LAN B for example s...

Страница 21: ...s on the Info page or in the LCD Lower_inside Interface Status Down L In Link Down Lower_outside Interface Status Down L OutLink Down The lower LAN expansion module is not configured correctly Check your cabling Since I installed the LAN expansion module my unit cannot see the corporate network at all Do you have two outside ports connected to the same hub The two outside ports must be connected t...

Страница 22: ...Chapter 2 Install into a 6500 Model 2 14 ...

Страница 23: ... apply only to these models which are hereafter collectively referred to as an 8500 9500 10000 model The following illustration shows a unit with two Gigabit LAN expansion modules for a total of three LANs using one 8500 9500 10000 model This is a maximum configuration you can install only one module if you wish Directions begin on the next page FAULT POWER STATUS CONSOLE LINK Tx Rx SPEED INSIDE O...

Страница 24: ...e to do so before you open the system or do any procedures can result in personal injury or equipment damage 2 Ground yourself WARNING Electrostatic discharge ESD can damage system components If an ESD station is not available wear a wrist strap attached to a metal part of the system If you don t have a strap touch some metal part of the box to ground yourself 3 If they are present remove the rack...

Страница 25: ...n expansion slot If you are installing two LEMs remove both blanks 6 Before installing the Gigabit LEM into a 8500 9500 10000 model ensure that the module has not been removed from its default C shaped bracket WARNING Using the incorrect bracket can damage the LEM or the 8500 9500 10000 model ...

Страница 26: ...card the jumpers you will have to replace them if you later wish to the standby function For additional information on enabling or disabling standby refer to the latest Getting Started Guide for your Packeteer unit available at http support packeteer com documentation L I N K T x R x S P E E D O U T S I D E I N S I D E L I N K T x R x S P E E D L I N K T x R x S P E E D ...

Страница 27: ...astic guides then push it toward the riser card until it snaps into place 9 If you are installing two Gigabit LEMs repeat steps 6 8 for the second module 10 Replace the door then replace the door screws SP EE D Tx Rx LINK SP EE D Tx Rx LINK OUTS IDE 10 100 1000M B Ethernet INSIDE ...

Страница 28: ...the following NIC modes for each LEM interface 10BaseT half duplex 10BaseT full duplex 100BaseT half duplex 100BaseT full duplex 1000BaseT full duplex Auto negotiate is the default network communication selection Note Selecting 1000BaseT full duplex causes the unit to auto negotiate per IEEE standard The screen above indicates that the built in LEM card for this unit is 100 Megabits the lower slot...

Страница 29: ... Inside interface settings also apply to the LEM interfaces 3 You can change security settings for all Inside and Outside interface communication if desired Click the Inside Interfaces and Outside Interfaces drop down lists to set access to all none or specified devices Setting Access Level unsecure default Enables unlimited access over the specified interface secure Blocks all access from the spe...

Страница 30: ...ough cable connected to LAN A 2 Reconnect this cable to the built in INSIDE port on the unit 3 Using the orange cross over cable connect the unit s built in OUTSIDE port to the router FAULT POWER STATUS CONSOLE LINK Tx Rx SPEED INSIDE OUTSIDE INSIDE INSIDE OUTSIDE OUTSIDE INSIDE OUTSIDE LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED WAN Router INPUT 100 240 MA...

Страница 31: ...h cable connected to LAN B 2 Reconnect this cable to the LEM s INSIDE port 3 Using the orange cross over cable connect the LEM s OUTSIDE port to the router FAULT POWER STATUS CONSOLE LINK Tx Rx SPEED INSIDE OUTSIDE INSIDE INSIDE OUTSIDE OUTSIDE INSIDE OUTSIDE LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED WAN Router INPUT 100 240 MAX 50 60Hz WAN LAN B LAN A ...

Страница 32: ... cable connected to LAN C 2 Reconnect this cable to the LEM s INSIDE port 3 Using the orange cross over cable connect the LEM s OUTSIDE port the router FAULT POWER STATUS CONSOLE LINK Tx Rx SPEED INSIDE OUTSIDE INSIDE INSIDE OUTSIDE OUTSIDE INSIDE OUTSIDE LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED LINK Tx Rx SPEED WAN Router INPUT 100 240 MAX 50 60Hz WAN LAN B LAN A LAN C ...

Страница 33: ...ould create a class for each subnet and put classes such as POP3 under each subnet class Note Even though traffic classes are combined each LAN s traffic is an individual flow 8500 9500 10000 models cannot route traffic between LANs For example if one LAN has public servers and the other does not the security of the non public LAN will not be compromised Traffic between LANs LAN A to LAN B for exa...

Страница 34: ...ges appears on the Info page or in the LCD Lower_inside Interface Status Down L In Link Down Lower_outside Interface Status Down L OutLink Down The lower LAN expansion module is not configured correctly Check your cabling Since I installed the LAN expansion module my unit cannot see the corporate network at all Are two outside ports connected to the same hub The two outside ports must be connected...

Страница 35: ...posite you may have installed an older LAN Expansion Module into a Packeteer 10000 series Check the packaging for the LEM module and verify its serial number the Packeteer 10000 series requires a LEM2G 1000M T or LEM2 1000M T with a serial number greater than 006 10010001 or a LEM2G 1000M SX or LEM2 1000M SX with a serial number greater than 007 10010001 If the LEM has a smaller serial number remo...

Страница 36: ...Chapter 3 Install into a 8500 9500 10000 Model 3 14 ...

Страница 37: ... outlet is located installed near the equipment and is easily accessible CAUTION THIS UNIT MAY HAVE MORE THAN ONE POWER SUPPLY CORD Disconnect all power supply cords before servicing to avoid electric shock INSTALLATION ELECTRICAL TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE GROUNDED Power plug must be connected to a properly wired earth ground socket outlet An improperly wired socket outlet coul...

Страница 38: ...ment and make sure you have over current protection The equipment is properly grounded No objects are placed on top of the unit Operating Temperature This product is designed for an ambient temperature of 32 to 104 F 0 to 40 C All Countries Install product in accordance with local and national electrical codes CAUTION RISK OF ELECTRIC SHOCK An improperly wired socket outlet could place hazardous v...

Страница 39: ... une prise femelle correctement mise à la terre Sinon des tensions dangereuses risqueraient d atteindre les pièces métalliques accessibles à l utilisateur ATTENTION Pour ce qui est de la protection contre les courts circuits surtension ce produit dépend de l installation électrique du local Vérifier qu on fusible ou qu un disjoncteur de 15A 250V est utilisé sur les circuits de CC ATTENTION Il y a ...

Страница 40: ...hnlichen vom Hersteller empfohlenen Typ ersetzen Verbrauchte Batterien müssen per den Instructionen des Herstellers verwertet werden Warning Read the installation instructions before connecting the system to the power source Attention Avant de brancher le système sur la source d alimentation consulter les directives d installation Warnung Vor dem Anschließen des Systems an die Stromquelle die Inst...

Страница 41: ... bzw in den USA 120 V Wechselstrom 15 A an den Phasenleitern allen stromführenden Leitern verwendet wird Warning The plug socket combination must be accessible at all times because it serves as the main disconnecting device Attention La combinaison de prise de courant doit être accessible à tout moment parce qu elle fait office de système principal de déconnexion Warnung Vor dem Anschließen des Sy...

Страница 42: ...component at the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Attention Pour éviter toute blessure corporelle pendant les operations de montage ou de réparation de cette unité en casier il convient de prendre des précautions spéciales afin de maintenir la stabilité du système Les directives ci dessous ...

Страница 43: ...llen zur Gewährleistung Ihrer Sicherheit dienen Wenn diese Einheit die einzige im Gestell ist sollte sie unten im Gestell angebracht werden Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das Gestell von unten nach oben zu laden wobei das schwerste Bau teil unten im Gestell anzubringen ist Wird das Gestell mit Stabilisierungszubehör geliefert sind zuerst die Stabilisatoren zu...

Страница 44: ...adiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications However there is no guarantee that interference Products EMI EMC Standards Safety Standards 1200 1550 1700 2500 3500 6500 7500 9500 10000 AS NZS 3548 Class A AS NZS 4252 1 ICES 003 Class A EMC Directive 89 336 EEC EMC Directive 73 23 EEC EMC D...

Страница 45: ...suggestions NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CAUTION Any modification to the equipment not expressly approved by Packeteer could void your authority to operate t...

Страница 46: ...ble occurs the user may be required to take corrective actions Internal access to Packeteer devices is intended only for qualified service personnel Canada Complianc e Statement Industry Canada Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur Appareils Numériques NMB 003 édictée ...

Страница 47: ...t are susceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Do not attempt to modify or use the supplied AC power cord if it is not the exact type required Ensure that the system is disconnected from its power source and from all telecom...

Страница 48: ...duct or component has reached its end of life you should dispose of it through a reputable licensed hazardous materials processor If you are located in one of the European Union Member States please refer to the product s end user license agreement for further information regarding the proper disposal reporting and or return of the product to Packeteer For additional information and to obtain retu...

Отзывы: