Page 16 of 35
TROUBLE SHOOTING GUIDE
1) INSUFFICIENT WATER TO THE BRUSHES
a) Make sure the solution flow control valve is open.
b) Confirm that there is water in the solution tank.
c) Make sure solution dispensing tubes are not clogged or
obstructed.
2) THE MACHINE DOES NOT CLEAN SATISFACTORILY
a) Check the condition of the brush or pad and replace them if necessary.
b) The brush should be replaced when the bristles reach a length of 5/8 inches (15mm).
3) THE SQUEEGEE DOES NOT DRY THE FLOOR WELL
a) Check that the squeegee blades are clean.
b) Adjust the inclination of the squeegee.
c) Confirm the vacuum hose is correctly fitted into its port in the
recovery tank and free
from obstructions.
d) Replace the squeegee blades if worn.
e) Check that the vacuum motor switch is on.
f) Check the squeegee height adjustment (see "MACHINE PREPARATION" section).
4) EXCESSIVE FOAM PRODUCTION
a) Check that a low foaming detergent has been used. If required, add a
small quantity of
defoamer liquid to the recovery tank.
More foam is generated when a floor is lightly
soiled. Use less detergent if this is the case.
Solution
Flow
Control
Lever
Содержание Z26BA
Страница 17: ...Page 17 of 35 Brush Deck Assembly Drawing 1...
Страница 19: ...Page 19 of 35 Main Frame Assembly Drawing 2...
Страница 21: ...Page 21 of 35 Squeegee Arm Assembly Drawing 3...
Страница 23: ...Page 23 of 35 Squeegee Assembly Drawing 4...
Страница 25: ...Page 25 of 35 Solution Tank Assembly Drawing 5...
Страница 27: ...Page 27 of 35 Recovery Tank Assembly Drawing 6...
Страница 29: ...Page 29 of 35 Vacuum Assembly Drawing 7...
Страница 31: ...Page 31 of 35 Switch Box Assembly Drawing 8...
Страница 33: ...Page 33 of 35 Electrical Schematic Drawing 9...