background image

14

Baffle Filter Clean Reminder 

Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory,  

These baffle filters are intended to filter out residue from cooking.  They need not be replaced on a regular 

basis but are required to be kept clean.  The filter clean reminder function in the microprocessor will 

automatically indicate by a flashing          when the baffle filters need to be cleaned after every 30 hours of 

use.  Filters can be cleaned by hand with non-abrasive soap or in a dishwasher.  Heavily soiled filters 

should also be soaked in grease cutting detergent prior to cleaning.

Baffle Filter Clean Indicator

When        flashes on display, the baffle filters 

installed are required to be cleaned.  This will occur 

after every 30 hours of use.

Re-setting Function

Reset the filter clean reminder timer when filters are 

cleaned and re-installed (with hood off).  Press and 

hold        for approximately 5 seconds, the display will 

appear; hold for approximately 5 seconds until        on 

display disappears        .  The filter clean reminder 

function is now reset and a new 30 hours elapse 

cycle is initiated.

F

Clean Filters

display < F > flashes

F

hold 5 sec. display from  < F > to <    >

To Reset

F

F

F

Features & Controls – 

Features

www.pacific-kitchen.com.tw

Содержание Trapeze CTP-E48BSX

Страница 1: ...Use Care and Installation Guide Trapeze CTP E48BSX CTP E54BSX CTP E60BSX www pacific kitchen com tw...

Страница 2: ...7 RRG 6SHFL FDWLRQV 8 Blower Preparation 9 11 Mounting the Range Hood 12 14 FEATURES CONTROLS Touch Controls 15 Features 16 Optional Remote Control 17 MAINTENANCE Cleaning and Installing Filters 18 TR...

Страница 3: ...etting on hood only when necessary WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE W...

Страница 4: ...electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest ed...

Страница 5: ...ers 2 Utensil Rails 1 8 Round Starting Collar 1 AC Power Wiring Box 1 Remote Blower Wire Harness Wiring Box 1 Motor Housing w Internal Motor Housing Flange 1 Remote Blower Motor Housing Flange www pac...

Страница 6: ...All exhaust must be ducted to the outside Some Ducting Options Installation Ducting Options sidewallcap w gravitydamper Soffit or crawl space RoofPitchw Flashing Cap External Blower Soffit or crawl s...

Страница 7: ...Cover Min 34 Max 51 1 2 Z1C 00TP Extension Min 47 Max 72 8 7 8 25 3 16 26 7 8 32 15 3 4 12 1 8 Min 21 5 8 Max 41 47 15 16 53 15 16 59 1 8 1 2 2 3 8 13 16 5 8 8 15 16 2 1 8 6 9 16 11 3 4 10 9 1 3 8 10...

Страница 8: ...0 VFUHZV IURP LQWHUQDO EORZHU hardware 3 Secure AC power wiring box to internal blower DQJH E 0 VFUHZV 4 Secure ground wire to underside of internal EORZHU DQJH E VFUHZ DQG washer 5 Connect 9 pin mole...

Страница 9: ...o 6 pin molex connector from control box Connect 2 pin plug from AC power cable to 2 pin plug from control box Secure cables to hood interior with zip ties and zip tie holders 5HPRYH LQWHUQDO EORZHU D...

Страница 10: ...od interior with zip ties and zip tie holders REMOTE BLOWER PREPARATION CONT 3 Secure AC power ground wire and remote blower ground wire to underside of remote EORZHU DQJH E VFUHZ DQG washer each 4 Se...

Страница 11: ...appliance Follow national electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly gro...

Страница 12: ...DFLQJ WKH IURQW DQG EDFN of hood FIG 3 LIW DVVHPEOHG XQLW DQG DWWDFK DOO DQJOH EUDFNHWV WR FHLOLQJ EUDFNHW 0DNH VXUH WKH WDEV RQ HDFK DQJOH EUDFNHW W EHWZHHQ WKH VORWV RQ WKH FHLOLQJ EUDFNHW 2QH KDOI...

Страница 13: ...rod set Utensil Rail Installation 1 Attach utensil rail to long side of hood canopy A small hole has been pre drilled into the canopy to provide a starting onto the canopy Use caution and be careful...

Страница 14: ...d lights Speed Selection The 3 speed levels are selected by pressing to decrease and to increase speed level The display indicates speed level selected Pressing when the hood is off will also turn it...

Страница 15: ...dishwasher Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning Baffle Filter Clean Indicator When flashes on display the baffle filters installed are required to...

Страница 16: ...install battery door and recycle old battery RF REMOTE FEATURES storage The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder FIG 1 The remote holder can...

Страница 17: ...r and clean cotton cloth Do not use corrosive or abrasive detergent or steel wool scoring pads which will scratch and damage surface For heavier soil use liquid degreaser using hood Maintenance Cleani...

Страница 18: ...The hood is not secured in place KHFN WKH LQVWDOODWLRQ RI WKH KRRG The unit is whistling OWHU LV QRW LQ WKH FRUUHFW SRVLWLRQ GMXVW WKH OWHUV XQWLO WKH ZKLVWOLQJ VWRSV 2 The duct pipe connections are...

Страница 19: ...19 Wiring Diagrams VOLTS HZ MAX AMPS 120 60 CBI290A 0 8 CBI600A 2 7 CTP E48 54 60BSX www pacific kitchen com tw INTERNAL BLOWER CIRCUIT DIAGRAM...

Страница 20: ...20 Wiring Diagrams VOLTS HZ MAX AMPS 120 60 CBE1000 6 0 PBN1000A 4 8 CTP E48 54 60BSX REMOTE BLOWER CIRCUIT DIAGRAM...

Отзывы: