4
DAILY OR REGULAR MAINTENANCE
1. Rinse solution and recovery tanks out after every use.
2. Twice a month, flush machine with a solution of white vinegar (one quart vinegar to two gallons of water) or anti-browning
solution mixed as directed. This will prevent build up of alkaline residue in the machine.
3. If spray jet becomes clogged, remove spray tip, wash thoroughly and blow dry.
PERIODIC MAINTENANCE
1. Periodically inspect all hoses, electrical cable and connections on the machine. Frayed or cracked hoses should be replaced
to eliminate vacuum or water pressure loss. Check power cable for damage. Repair or replace damaged cord to prevent
fire or electric shock.
PROTECT FROM FREEZING
Do not allow machine to freeze with water in the solution or recovery system. To avoid damage, run pump dry before ex-
posing to freezing temperatures.
If machine is stored for a long period of time in freezing temperatures, completely drain machine of all solution or recov-
ered water. Pour undiluted antifreeze into the solution tank and squeeze hand tool lever until antifreeze solution is present
in the solution system.