SECTION 3 INSTALLATION
23
3.3 INPUT POWER CONNECTION (continued)
The ACX Power Source is provided with a terminal block for input power connection. This allows
hard-wired connection for system applications or attachment of an appropriate input power cord.
Refer to Paragraph 2.1.1 for minimum input service requirements for various input voltages and
size the input cable wires accordingly.
Refer to the table below for the proper wire color of each connection.
Wire Color
( USA)
Wire Color
( Europe)
LINE ( HI )
Black
Brown
NEUTRAL ( LO )
White
Blue
GROUND ( PE * )
Green
Green-Yellow
* Protective Earth
NOTE: It is the user's responsibility to meet all local and national electrical codes when installing
this equipment. This equipment is classified as a permanently connected device. As
such, proper installation requires the use of a circuit breaker in the building wiring
installation which is sized appropriately to protect the facility wiring. A switch or circuit
breaker shall be in close proximity to the equipment and marked as the disconnecting
device for the equipment.
FIGURE 3.3
INPUT AND OUTPUT CONNECTIONS
TO
USER
GROUND
CHASSIS
CONNECTION
ATTACHED
TO STUD AS
SHOWN
INPUT
LINE
PE/GND
HI
LO