Page 45
Kore 7th Manual / kHLab Edition
5.7. ATO / Temp config
DC pump
group box
Refill time (in seconds)
Time in seconds defining how long the DC pump will
work when water low level sensor is activated. After
four unsuccessful attempts the pump will be turned
off (to prevent damage). It’s highly advised to select
„Unsuccessful water refill Alarm check-box so you can
be notified upon failure.
Manual turn on/off
Allows selecting the flow rate manually (flow adjust in
40-100% range).
Short beep after proper refill
Enabling this option will cause a beep after each refill
of water.
Sound alarm
Turn on/off sound alarm when high level sensor is
activated.
Choose alarm type
Allows you to select sound signal generated by the
doser.
Test alarm
Test sound alarm
Reset ATO alarm
Allows resetting the ATO after four unsuccessful refills.
Temperature
group box
Reset High/Low temp
Erase highest/lowest temperature record from doser
memory.
Temperature alarm
Turn on/off sound alarm for temperature settings