Frequency Range
Settings
E2 jumper sets the VCO maximum output pulses frequency range.
There are two frequency ranges selectable by a jumper to enhance
output speed resolution.
E2
Frequency Range
IN
Low Frequency
250 Khz maximum VCO output pulses
OUT
High Frequency
500 Khz maximum VCO output pulses
Coarse Resolution (E2 Removed)
Fine Resolution (E2 Installed)
3 - 10
6415 Installation and Hardware Reference Manual - Rev E
Speed Resolution (62.5Khz/V)
0
8V
0
500Khz
2V
4V
6V
375Khz
250Khz
125Khz
Speed Resolution (31.25Khz/V)
0
8V
0
250Khz
2V
4V
6V
62.5Khz
125Khz
187.5Khz