REVISION C
BMX SERIES III CONSOLE
35
PACIFIC RESEARCH & ENGINEERING
2.8.4 Two-Studio Monitor Module Remote Control
The Two-Studio Monitor Module is equipped with many of the same audio and logic features provided
in the Control Room Monitor Module. The schematic below illustrates the full remote control
capability of each of the two Studio logic connectors.
DIM
5
4
MUTE
TALKBACK
3
2
LOGIC + 12 VDC
1
LOGIC COMMON
6
STU. WARNING
7
LOGIC COMMON
9
MUTE STUDIO
8
DIM STUDIO
DIM
MUTE
TALKBACK
+ 12 VDC
NC
C
NO
WARNING
MUTE
DIM
1N4001
+
-
12
VDC
NOTES:
A)
Button switches are momentary-action.
B)
Lamps are 12-14 volt, 80 mA.
C)
Relay is 12 volt DC, 100 mA maximum.
D)
When DIM and MUTE tallies are connected as shown above,
switch lamps will be illuminated at all times.
While it is unlikely that a “typical” studio installation will use all of these features, it is important to
understand what is available, along with the potential applications.
The DIM control input may be used to remotely control the dim function of the Studio Monitor Module.
Typical applications include equipping the Studio door with a “door open” switch, or a telephone set
with an “off-hook” switch to automatically dim the Studio speakers whenever the door opens or the
telephone is picked up.