permanent / minimum-
maximum measuring
Used to measure room diagonals (maximum values) or
horizontal distance (minimum values)
min.
max.
8.532
m
The minimum and maximum
distance measured is displayed
(min,max.). The last value
measured is displayed in the main
line.
Stops permanent / minimum- maximum measuring.
add / subtract
The result is
shown in the
main line and
the measured
value above.
Partial
Measurements:
Press + or -
after starting
the first
measurement.
Measure and
add or subtract
distances.
Finish with
DIST. Measure
2nd length.
area
volume
pythagoras
(
3
-point)
pythagoras
(partial Height)
switching on/off
OFF
2 sec
Press ON
button 2
sec to start
continuous
laser mode.
1x
2x
Device is
turned OFF.
Undo last action.
Leave actual function, go to
default operation mode
If the message :inFo” appears
with a number, observe the
instructions in section
“message Codes”.
Example at left.
adjusting measuring
reference / tripod
Distance is measured from the
front of the device.
Distance is
measured from
the tripod thread
permanently.
Distance is measured from
the rear of the device
(standard setting).
beep on/off
2 sec simultaneously
2 sec simultaneously
clear
message code
illumination on/off
1
2
3
The result is shown
in the main line and
the measured
value above.
8.294
m
The result is
shown in the main
line and the
measured
distance above.
Pressing the
measuring key for
2 sec in the
function activates
automatically
Minimum or
Maximum
measurement.
Aim Laser at
upper point.
1
2
3
4
5
6
2.602
m
7
The result is shown
in the main line
and the measured
distance above.
Pressing the
measuring key for
2 sec in the
function activates
automatically
Minimum or
Maximum
measurement.
1
2
3
Aim laser at
2nd point.
Aim laser at
rectangular
point.
1
2
3
7
4
5
6
Aim laser at
rectangular point
Aim laser at
upper point.
Aim laser at
lower point.
Aim laser at
first target point..
1
2
3
Aim laser at
second target
point..
4
5
6
7
Aim laser at
first target point.
1
2
3
4
5
Press 2 sec AREA / VOLUME key to get 2nd results.
Press 2 sec AREA / VOLUME key to get 2nd results.
7.332
m
12.847
m
The next
measurement
is added to the
previous one.
The next
measure-
ment is
subtracted
from the
previous
one.
The result is shown in the
main line and the measured
value above. This process
can be repeated as required. The same process can be
used for adding or subtracting areas or volumes.
1
2
3
Aim active
laser target.
measuring single
distance
1
2
3
stake out
memory
(
10
last displays)
8.294
m
10
10 last displays
are displayed.
8.294
m
10
.
Navigates
through
10 last
displays.
2 sec
The value from
the main line
can be used for
further
calculations.
2 sec
Memory is completely deleted.
simultaneously
1
2
3
delete memory
Adjust Value
Approve value and
start measurement.
3
1
2
4
Move device slowly
along the stake-
out line. The distance
to the next stake-out
point is displayed.
When approaching a stake out point to less
than 0.1 m the instrument starts to beep.
The function can be stopped by pressing
the CLEAR/OFF button.