- 8 -
WARNING
: Batteries emit hydrogen and oxygen gas.
•
Keep sparks and open flame away.
•
Do not smoke near the machine.
•
Charge batteries in a well-ventilated area with the battery compartment open.
WARNING
: Do not wear jewelry when working near moving or electrical components.
CHARGING
WARNING
: Do not plug in the charger cable if wall cord or battery harness is damaged.
NOTE
:
Do not use an extension cord with the battery charger. This will void the charger warranty.
NOTE
:
Ensure battery charging and storage locations comply with OSHA and any governing agencies’ standards based on
your particular location and application.
This machine is equipped with an on-board charger. The cord for the charger can be located in the cord storage compartment under the
seat.
The charger status LED’s (used to indicate the charger’s status while plugged in) can be viewed through the view window located on
the vertical kick panel below the seat.
LED INDICATION
MEANING
GREEN flashing (2 seconds) Charger is set for AGM batteries
YELLOW flashing (continuous) Unsuitable battery connected or output short circuit
RED flashing (2 seconds)
Charger is set for Lead Acid batteries
RED flashing (continuous)
Safety timer exceeded or internal short circuit
Solid GREEN
The unit is fully charged
Solid YELLOW
Phase 2 of charging is in progress
Solid RED
Charging cycle has begun
NOTE
:
Seat assembly must remain open while charging to prevent damage to the charger power cord.
CHARGER SETTINGS
SW1
DP2
DP1
APPLICATION
OFF
ON
LEAD-ACID (WET) BATTERIES
OFF
OFF
AGM (MAINTENANCE FREE)
SW2
DP2
DP1
CHARING CURRENT
ON
OFF
20A
OFF
ON
25A
OFF
OFF
25A
SW1: Sets the current profile of the charger to the particular battery that is installed.
SW2: Set the current level of the charger based on the
amp-hour rating for the particular batteries installed.
CHARGING CURRENT
BATTERY AMP HOUR RANGE (20h)
20A
150-240 Ah
25A
220-315 Ah
Содержание RS28
Страница 23: ...20 RETURN TO TABLE OF CONTENTS PAGE INTENTIONALLY LEFT BLANK...
Страница 43: ...RETURN TO TABLE OF CONTENTS 40 PAGE INTENTIONALLY LEFT BLANK...
Страница 52: ...49 RETURN TO TABLE OF CONTENTS ELECTRICAL DIAGRAMS...
Страница 53: ...RETURN TO TABLE OF CONTENTS 50 ELECTRICAL DIAGRAMS...
Страница 54: ...RETURN TO TABLE OF CONTENTS 51 DATE MAINTENANCE LOG...
Страница 55: ...52 RETURN TO TABLE OF CONTENTS DATE MAINTENANCE LOG...
Страница 57: ...54 RETURN TO TABLE OF CONTENTS PAGE INTENTIONALLY LEFT BLANK...
Страница 58: ...www pacificfloorcare com...