Maintenance

1.  Burn wood only, dry and well seasoned.  The denser or 

heavier the wood when dry, the greater its heat value.  
This is why hardwoods are generally preferred.  Green 
or wet wood will cause a rapid buildup of creosote.  If you 
feel it is necessary to burn wet or unseasoned wood, do 
so only with the air inlet set open enough to maintain a 
good strong fi re and fairly high chimney temperatures.  
Do not attempt to burn overnight using green or wet 
wood.  Wet wood can cause up to 25% drop in heater 
output, as well as contributing signifi cantly to creosote 
buildup.

WARNING:  Never use chemicals or any other volatile 
liquid to start a fi re.  Do not burn garbage, or fl ammable 
fl uids such a gasoline, naptha, or engine oil.  We strongly 
recommend that smoke detectors be installed. 

2.  Remove ashes frequently.  Embers can roll out the door 

and create a fi re hazard.  Maintain a 1" minimum ash 
base.

3.  If glass becomes darkened through slow burning or poor 

wood, it can readily be cleaned with any fi replace glass 
cleaner when stove is cold.  Never scrape with an object 
that might scratch the glass.  The type and amount of 
deposit on the glass is a good indication of fl ue pipe 
and chimney buildup. A light brown dusty deposit that 
is easily wiped off usually indicates good combustion 
and dry, well-seasoned wood and therefore relatively 
clean pipes and chimney.  On the other hand, a black, 
greasy deposit that is difficult to remove is a result of 
wet and green wood and too slow a burning rate. This 
heavy deposit is building up at least as quickly in the 
chimney.

WARNING:  Only use materials supplied by the manu-
facturer when doing maintenance or replacements.

4.  DOOR GASKET - The gasket used by Pacifi c Energy 

requires only light pressure to seal.  This will prolong seal 
life. It is important that the door seal be maintained in 
good condition.  Periodically inspect seals and replace 
if necessary.  Follow instructions included in the Service 
Kit (SVCK.10178) obtainable from your nearest Pacifi c 
Energy Dealer.

5.  DOOR GLASS - Do not slam loading door or otherwise 

impact glass.  When closing door, make sure that no logs 
protrude to impact the glass.  If the glass gets cracked 
or broken, it must be replaced before using the stove.  
Replacement glass can be obtained from your Dealer.  
The size required is 9-1/8 x 15-5/8 x 5 mm Robax.  Ce-
ramic glass must be used.  Do not substitute with any 
other type.

To remove broken glass, undo the four retaining screws 
and remove the frame noting position for re-assembly. 

 

Remove all particles of glass.  Be careful as they are very 

sharp. Install new glass complete with gasket.  Replace 
frame and screws.

WARNING:  Do not overtighten, tighten screws very 
carefully.

 

- Do not clean glass when hot

 

- Do not use abrasive cleaners on glass

6.  The area where boost combustion air enters the fi rebox 

must be kept clear of excessive ash buildup which will 
block air fl ow.  This area is at the front of the fi rebox.

7.  Do not store wood within heater installation clearances, 

or within the space required for fuel loading and ash 
removal.  Keep the area around the heater clean and 
free of all loose combustibles, furniture, newspapers, 
etc.

8.  If gold door requires cleaning, use mild soap and water 

only.  Use of abrasive cleaners will void warranty.

9.  Establish a routine for the fuel, wood burning and fi ring 

technique.  Check daily for creosote buildup until experi-
ence shows how often you need to be cleaning to be 
safe.

10. Be aware that the hotter the fi re, the less creosote is 

deposited.  Weekly cleaning may be necessary in mild 
weather, even though monthly cleaning is usually enough 
in the coldest months when burning rates are higher.

11.  Instruct all members of your family on the safe operation 

of the heater.  Ensure they have enough knowledge 
of the entire system if they are expected to operate it. 
Stress the section on chimney fi res and the importance 
of following the steps outlined in “In Case of Chimney 
Fire”. 

Baffle Removal

The Insert and pipe should be removed from the fi replace 
to clean and inspect.  Only if this is not possible should you 
remove baffle assembly.

DO NOT OPERATE WITH BAFFLE ASSEMBLY OR IN-
SULATION REMOVED.

Baffle Assembly Removal

Remove retaining pin at the back top of the fi rebox,  just 
under the baffle.  Lift baffle up and pull forward to discon-
nect from the supply tube.  Tilt baffle sideways to drop down 
and remove from fi rebox.  Remove insulation to access 
fl ue outlet.

Inspect gasket between baffle and supply tube. If necessary, 
replace with gasket # 139.5 available from your nearest 
Pacifi c Energy Dealer.

Re-install baffle assembly and insulation by reversing 
order.

Содержание Wood Insert Design-D

Страница 1: ...ation directions Consult local building or officials about restrictions and installation inspection requirements in your area Pacific Wood Insert IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HO...

Страница 2: ...on 10 How to Test Your Wood 10 Lighting the Fire 10 Normal Operation 10 Restarting After Extended or Overnight Burns 10 More Wood More Heat 11 Proper Draft 11 Ash Removal 11 Disposal of Ashes 11 Creos...

Страница 3: ...rections Consult local building or fire officials about restrictions and installation inspection requirements in your area The services of competent installer certified by the Wood Energy Technical pr...

Страница 4: ...ening Ember protection Combustible floor beyond the hearth must be protected from hot embers by non combustible material extending 16 to the firing side and 8 to other sides of the unit Consult CAN CS...

Страница 5: ...uitable for wood burning use Check for creosote build up or other obstructions especially if it has not been in use for some time The existing fireplace damper is to be locked open or re moved complet...

Страница 6: ...g legs to level the Insert Note For better access the top of the casing may be re moved Fig 4 If it is necessary to get access to the connector pipe through the flue outlet of the Insert the baffle ca...

Страница 7: ...e enclosed hardware Slide part F into the back corners of the trim and tighten screws Ensure the mitred corners fit tightly and evenly Fig 6 4 Slide the assembled trim over the surround from the top F...

Страница 8: ...erse order to their removal 8 Slide pre assembled surround into the friction fit tabs on the inside of the outer casing DO NOT LIFT THE SURROUND ASSEMBLY BY GRASPING THE TRIM The surround is held in p...

Страница 9: ...pply Once removed combustion air is drawn from the room into the lower front of the Insert Removal The O A cover should be removed prior to instal lation For better access tip the Insert onto its back...

Страница 10: ...er in the centre of the heater and criss cross with several pieces of dry kindling Add a few small pieces of dry wood on top 3 Ignite the paper and close the door 4 After the fire as established itsel...

Страница 11: ...g the smoke the ideal place to condense In summary a certain amount of creosote is inevitable and must be lived with Regular inspection and cleaning is the solution The use of dry seasoned wood and am...

Страница 12: ...peed Control Blower Thermo Switch By pass Rocker Switch Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are dangerous Chimney inside temperatures can exceed 2000...

Страница 13: ...sing the stove Replacement glass can be obtained from your Dealer The size required is 9 1 8 x 15 5 8 x 5 mm Robax Ce ramic glass must be used Do not substitute with any other type To remove broken gl...

Страница 14: ...w Bolt WODC 1461 12 Glass Clamp Set 4 pc SSER 1425 13 Glass Bar Set 2 pc WODC 414001 14 Replacement Glass c w Tape DR31 WGLKIT 15 Door Gasket Kit DR31 WDGKIT 16 Door Casting Arched Black CAST 31ST Do...

Страница 15: ...heat storage and the thermal insulation keeps the combustion zone hot Active flaming takes place during the first part of the burn During this storage heat is stored in the mass of the unit and is la...

Страница 16: ...ace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Area too large 4 Poor insulation or open concrete Won t Burn Overnight 1 Air control set too hi...

Страница 17: ...17 NOTES...

Страница 18: ...18 NOTES...

Страница 19: ...DIRECT FLUE CONNECTION ASSEMBLY OPTIONAL COMPONENTS FAN KIT ELECTRICAL RATING 115V 60HZ 1 AMP ROUTE CORD AWAY FROM UNIT FOR USE WITH SOLID WOOD FUEL ONLY DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD F...

Страница 20: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net Technical Support 1 888 715 2398 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...

Отзывы: