MINIMUM CLEARANCE TO COMBUSTIBLES (MEASURED FROM INSERT BODY)
DÉGAGEMENT MINIMUM AUX COMBUSTIBLES
A)  

ADJACENT SIDEWALL/ 

203 MM / 8 IN

 PAROI 

LATÉRALE 

ADJACENTE

B) 

MANTEL 

381 MM / 15IN

C) 

TOP FACING/ 

381 MM / 15IN

 REVÊTEMENT 

SUPÉRIEUR

D) 

SIDE FACING/ 

203 MM / 8 IN

 REVÊTEMENT 

LATÉRAL

E) 

FIRING SIDE, CANADA 

457 MM / 18 IN

 

FIRING SIDE, U.S.A. 

406 MM / 16 IN

 

EPREUVE DU FEU

F) 

OTHER SIDES 

200 MM / 8 IN

 AUTRES 

CÔTÉS.

INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED 50 MM / 3 IN ABOVE AN ADJACENT COMBUSTIBLE FLOOR.  

DATE OF MANUFACTURE

INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND  OPERATING  INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND  INSTALLATION INSPECTION IN 
YOUR AREA. INSTALL AND USE ONLY IN MASONRY OR  FACTORY BUILT  FIREPLACE. DO NOT  CONNECT THIS UNIT TO A 
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
COMPONENTS REQUIRED FOR INSTALLATION : FULL FLUE LINER  CONFORMING TO CAN/ULC-S635 OR CAN/ULC-S640. 
IN U.S.A. FLUE LINER CONFORMING TO UL-1777 OR DIRECT FLUE  CONNECTION ASSEMBLY.
ELECTRICAL RATING 115V, 60HZ, 1.1 AMP. ROUTE POWER CORD AWAY FROM UNIT.
FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE-BUILD WOOD FIRE DIRECTLY ON 
HEARTH. REPLACE GLASS ONLY WITH CERAMIC GLASS. INSPECT AND CLEAN CHIMNEY FREQUENTLY-UNDER 
CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY.OPERATE ONLY WITH FEED DOOR CLOSED.  
OPEN TO FEED FIRE ONLY.

MADE IN CANADA

F

M

A

M

J

J

A

S

O

N

D

2011

2012

2013

2014

2015

2016

U.S. ENVIRONMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990
PARTICULATE EMISSION STANDARDS

J

LISTED SOLID WOOD FUEL FIREPLACE INSERT / APPAREIL DU 
TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMINÉE
CERTIFIED FOR USE IN CANADA AND U.S.A./CERTIFIE AU 
CANADA ET AUX ETATS-UNIS
TESTED TO / ÉPROUVÉ SELON:
ULCS628-93 / UL1482 (2011)
MODEL / MODÈLE:    SUMMIT INSERT

SERIES / SÉRIE:   C

230413 5050.7621 SINC-1

CAUTION

HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.  
SEE NAMEPLATE AND INSTRUCTIONS.

MANUFACTURED BY:

PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

2975 ALLENBY RD., DUNCAN, BC  V9L 6V8

CLEARANCE TO COMBUSTIBLE
CONSTRUCTION

F

ADJACENT SIDE W

A

LL

A

B

D

E

C

F

   WN#16831           ETL# 4001507

INSTALLEZ ET UTILISEZ SELON LES INTRUCTIONS D’INSTALLATION ET D’OPÉRATION DU PACIFIC ENERGY.  BÂTIMENT 
OU POMPIERS LOCAUX DE CONTACT AU SUJET DES CODES, RESTRICTIONS ET D’INSPECTION D’INSTALLATION 
DANS VOTRE SECTEUR. INSTALLEZ ET  EMPLOYEZ SEULEMENT EN MAÇONNERIE OU CHEMINÉE CONSTRUITE PAR 
USINE. NE RELIEZ PAS CETTE UNITÉ À UNE CONDUITE DE CHEMINÉE DE CHEMINÉE SERVANT UN AUTRE APPAREIL. 
MATERIEL REQUIS POUR L INSTALLATION:PLEIN REVÊTEMENT DE CONDUITE DE CHEMINÉE  CONFORMÉMENT À 
CAN/ULC-S635 OR CAN/ULC-S640. ÉLECTRIQUE 115V, 60HZ, 1.1 AMP. ITINÉRAIRE POWERCORD À PARTIR D’UNITÉ. 
POUR UTILISATION AVEC  COMBUSTIBLE AU BOIS  SEULEMENT. N’UTILISEZ PAS LA GRILLE OU N’ÉLEVEZ PAS LE 
FEU EN BOIS DE FIRE-BUILD DIRECTEMENT SUR LE FOYER. REMPLACES LA VITRE AVEC UNIQUEMENT DE LA 
VITRE CÉRAMIQUE.  INSPECTEZ ET NETTOYEZ LA CHEMINÉE FRÉQUEMMENT-DANS CERTAINES CONDITIONS 
D’UTILISATION, L’HABILLAGE DE CRÉOSOTE PEUT SE PRODUIRE RAPIDEMENT. OPÉREZ SEULEMENT AVEC LA PORTE 
D’ALIMENTATION FERMÉE. OUVREZ-VOUS POUR ALIMENTER LE FEU SEULEMENT.

602

The certfi cation label is located on the left side casing of the insert.

CERTIFICATION 

LABEL

Содержание SUMMIT INSERT

Страница 1: ...icials about restrictionsandinstallationinspectionrequirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS TESTED and LISTED to ULC S628 UL 1482...

Страница 2: ...ney Fire 15 Avoiding a Chimney Fire 15 Maintenance 16 Baffle Removal 16 Appendix A 17 Understanding Operating Your Pacific Energy Stove 17 Troubleshooting 18 Firebrick Installation 19 Replacement Part...

Страница 3: ...ly installed a house fire may result For your safety follow the instal lation directions Consult local building or fire officials about restrictions and installation inspection require ments in your a...

Страница 4: ...et Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has permanent warping greater than this or h...

Страница 5: ...nt combustible floor Ember protection Combustible floor in front of the fireplace insert must be protected from hot embers by non combustible material extend ing 16 USA and 18 CANADA to the firing sid...

Страница 6: ...14 24 Dimensions 40 7 8 23 5 16 25 3 8 27 9 16 B A 28 7 8 18 10 7 8 21 6 5 8 12 1 4 22 15 16 9 1 8 Mantel Clearances A 15 B 15 MANTEL CLEARANCE CHART A B 12 4 REG SURROUND A 48 3 4 B 32 1 16 SURROUND...

Страница 7: ...urning use Check for creosote build up or other obstructions especially if it has not been in use for some time Have chimney swept Theexistingfireplacedamperistobelockedopenorremoved completely WARNIN...

Страница 8: ...ove cement and insert into collar Screw in fasteners to secure 8 Attach a rain cap to the end of the liner A storm collar may be used if desired 9 Reattach casing top with screws previously removed Co...

Страница 9: ...ir inlet or outlet ports This includes the circulating air chambers in a steel fireplace or metal heat circulator 5 Alteration of the fireplace in any manner is not permitted with the following except...

Страница 10: ...age 11 and then remove the decorative top by loosening the two wing bolts underneath and sliding it out of the brackets Fig 9 4 Slide the assembled surround from the top down and engage in slots on su...

Страница 11: ...and thermal snap switch Take note of where the wires are routed and secured They must be positioned correctly to avoid damage 3 Loosen the two bolts that secure the ash lip to the firebox carefully li...

Страница 12: ...mounting bracket and relocate to left hand fan mounting bracket Fig 20 21 8 Reconnect the wires to the fans Fig 22 and thermal snap switch Fig 23 refit ash lip sides and top Ensure that the power cab...

Страница 13: ...have shut the control down too soon or you are using too low a setting As every home s heating needs vary i e insula tion windows climate etc the proper setting can only be found by trial and error an...

Страница 14: ...or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed theyshouldberetainedintheclosedcontaineru...

Страница 15: ...ccurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire 1 Highest smoke densities occur when a large amount of wood is added to a bed of hot coals and the air inl...

Страница 16: ...s or any other volatile liquid to start a fire Do not burn garbage or flam mable fluids such a gasoline naptha or engine oil We strongly recommend that smoke detectors be installed 2 Remove ashes freq...

Страница 17: ...ation The high mass weight acts as a heat storage and the thermal insulation keeps the combustion zone hot Active flaming takes place during the first part of the burn During this stage heat is stored...

Страница 18: ...1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is set to...

Страница 19: ...mm x 32 mm 3245 501 Summit Insert Wood Stove This package contains 17 full size firebricks as well as 7 various cut size bricks With the woodstove in the upright position install firebricks as follow...

Страница 20: ...ck CAST 46ST Door Casting Arched Gold CAST 46GDA Door Casting Arched Nickel CAST 46NI Door Casting Arched Brushed Nickel CAST 46BNA 23 Door Handle Assembly c w Wood Handle and Nut WODC 4147C 24 Baffle...

Страница 21: ...SINC 250314 24 21 Fig 25...

Страница 22: ...22 SINC 250314 24 NOTES...

Страница 23: ...ICULATE EMISSION STANDARDS J LISTED SOLID WOOD FUEL FIREPLACE INSERT APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMIN E CERTIFIED FOR USE IN CANADA AND U S A CERTIFIE AU CANADA ET AUX ETATS...

Страница 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD Phone 1 250 748 1184 www pacificenergy net 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...

Отзывы: