14
220514-20
Troubleshooting
PROBLEM
CAUSE
CURE
GLASS IS DIRTY
1. Wood is wet
- Use dry wood
2. Turning down air control
- Do not turn down until:
too soon
a) there is a good bed of coals
b) the wood is charred
3. Draft too low
- Improper chimney height and/
or
diameter
- Chimney plugged or restricted, check fl ue
- Provide outside air for combustion
4. Door gasket leakage
- Replace gasket
-
Check
latch
EXCESSIVE CREOSOTE BUILDUP
See 1,2,3, above.
LOW HEAT OUTPUT
1. Wood is wet
- Use dry wood
2. Fire too small
- Build a larger fi re
3. Draft too low
- Chimney plugged or restricted.
Inspect
and
clean
STOVE WON'T BURN
1. Combustion air supply blocked
- Check outside air supply for
obstruction
- Check that room air cover is
removed
2. Draft too low
- Chimney plugged or restricted
Inspect and clean
- Chimney oversized or otherwise
unsuitable,
Consult
dealer
Appendix A