background image

 Rating Label 

PLEASE SAVE THESE INSTRUCTIONS

This manual describes the installation and operation 
of the Pacific Energy, NEO 2.5 LE Freestanding wood 
heater. 

SAFETY NOTICE:  If this stove is not properly 
installed, a house fire may result. For your safety, 
follow the installation instructions. Contact local 
building or fire officials about restrictions and 
installation inspection requirements in you area.

Please read this entire manual before you install 
and use your new room heater. Failure to follow 
instructions may result in property damage, bodily 
injury, or even death.

This heater meets the 2020 U.S. Environmental 
Protection Agency's cordwood emission limits for 
wood heaters sold after May 15, 2020 Tested to 
ASTM E3053.

Model NEO 2.5 LE: 2.0 g/hr..

Under specific test conditions this heater has been 
shown to deliver heat at rates ranging from 15,850 to 
59,850 Btu/hr.

EPA Certified Emissions

2.0 grams per hour

LHV Tested Efficiency 1

78%

HHV Tested Efficiency 2

72%

EPA BTU Output 3

15,845 to 59.861 btu/hr.

Maximum Wood Length

18 inches

Ideal Wood Length 

17 inches

Fuel

Seasoned Cord wood

1  Weighted Average Lower Heating Value (LHV) effi-
ciency as tested using CSA B415 Performance testing of 
solid-fuel-burning heating appliances. LHV assumes the 
moisture is already in a vapour state so there is no loss 
of energy
2 Weighted Average Higher Heating Value (HHV) effi-
ciency as tested using CSA B415 Performance testing of 
solid-fuel-burning heating appliances. HHV includes the 
energy required to vaporize the water in the fuel
 3 The range of BTU outputs is based on efficiency using 
CSA B415 Performance testing of solid-fuel-burning 
heating appliances and burn rates from the low and high 
EPA tests using Douglas Fir dimensional lumber.

Efficiency and BTU Output

 

A.

 

12 in. / 305 mm

 B.

 

12 in. / 305 mm

 C.

 

8 in. / 205 mm

 D.

 

23-1/2 

in. 

/ 600 

mm                  

 E.

 

15 

in. 

/ 380 

mm              

 F.

 

17 

in. 

/ 430 

mm 

              

CERTIFIED FOR CANADA

 AND U.S.A.

  - 

MODEL

 / MODÈLE:

     

NEO 2.5

 LE 

     

NEOST

ONE

 2.5 LE 

        

NEWCASTLE

 2.5 LE

LISTED ROOM HEA

TER, SOLID FUEL

 TYPE. 

ALSO FOR USE IN MOBILE HOMES

CERTIFIED T

O / CERTIFIÉ POUR: CAN/ULC S627-00 (R2016) / UL

 1482-201

Refer to Intertek’

s Directory of Building Products for detailed information

MINIMUM CLEARANCES T

COMBUSTIBLE MA

TERIALS/

DÉGAGEMENTS 

MINIMALES AUX 

MA

TÉRIAUX COMBUSTIBLES

DO NOT

 REMOVE 

THIS LABEL

RESIDENTIAL

 and MOBILE HOME 

INST

ALLA

TION USING DOUBLE 

W

ALL

 CONNECT

OR /

 INST

ALLA

TION 

RÉSIDENTIELLE A

VEC 

DÉGAGEMENT MINIMAL, UTILISANT 

UN RACCORD DE MUR DOUBLE

RESIDENTIAL

 INST

ALLA

TION 

USING SINGLE W

ALL

 

CONNECT

OR */

INST

ALLA

TION RÉSIDENTIELLE 

UTILISANT UN RACCORD DE MUR 

SIMPLE

 IN CANADA

 

G.

 

18 INCHES / 450 MM

 AU 

CANADA

 

H.

 

8 INCHES / 200 MM

 

I. 

8 INCHES / 200 MM

 IN U.S.A.

 

G.

 

16 INCHES / 405 MM

  

H.

 

5 INCHES / 127 MM

 

I. 

0 INCHES / 0 MM

 C#4001507

A.

 SIDEW

ALL

 T

O UNIT/

 

MUR DE CÔTE / 

APP

AREIL

B.

 BACKW

ALL

 T

O UNIT/

M

UR DE FOND / 

APP

AREIL

C.

 CORNER T

O UNIT/

COIN 

/ APP

AREIL

D.

 SIDEW

ALL

 T

O CONNECT

OR/

MUR DE CÔTE / RACCORD E.

 BACKW

ALL

 T

O CONNECT

OR/

MUR DE FOND / RACCORD F. 

CORNER T

O CONNECT

OR/

COIN / RACCORD

BACK  I

HEA

TER

G

SIDE

H

FRONT

SIDE

H

COTE

COTE

DEV

ANT

POELE

DOS

MADE IN CANADA/ 

FABRIQUÉ AU 

CANADA

100003378

230919

MANUF

ACTURED BY/ 

FABRIQUÉ P

AR:

PACIFIC ENERGY

 FIREPLACE PRODUCTS L

TD.

2975 

ALLENBY

 RD., DUNCAN, BC  V9L

 6V8

ADJACENT

 W

ALL

BACK W

ALL

D

A

SIDE WALL

B

E

ADJACENT W

ALL

F

C

MUR COTE

MUR ARRIERE

MUR ADJACENT

MUR ADJACENT

 

A.

 

8 in. / 205 mm 

 B. 

 

5 in. / 125 mm 

 C.

 

3 in. / 750 mm 

   

 D.

 

19 

1/2 

in. 

/ 495 

mm         

 E.

 

in. 

/ 205 

mm 

         

 F.

 

12 in. / 305 mm

  

D

ATE OF MANUF

A

CTURE

2.0

 g/hr

U.S. ENVIRONMENT

AL

 PROTECTION 

AGENCY

Certified to comply with 2020 P

ARTICULA

TE EMISSION ST

ANDARDS, 

using CORDWOOD.  T

ested to 

ASTM E3053 // 

Certifié conforme aux 

normes sur les émissions de particules de 2020. 

•  FOR USE WITH SOLID FUEL

 (CORDWOOD ) ONL

Y. DO NOT USE OTHER FUEL

 TYPES.  INST

ALL

 AND USE 

IN 

ACCORDANCE WITH THE MANUF

ACTURER’S INST

ALLA

TION 

AND OPERA

TING INSTRUCTIONS.

• 

CONT

ACT LOCAL

 BUILDING OR FIRE OFFICIALS 

ABOUT RESTRICTIONS, INST

ALLA

TION PERMIT 

AND 

 

INSPECTION 

IN 

YOUR AREA.

• 

DO NOT CONNECT THIS UNIT T

A CHIMNEY

 FLUE SER

VING 

ANOTHER 

APPLIANCE.

• 

USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECT

OR.

• 

UNIT CAN BE CONNECTED T

A LINED MASONR

Y CHIMNEY

 SUIT

ABLE FOR USE WITH SOLID FUELS.

• 

DO NOT OBSTRUCT THE SP

ACE BENEA

TH THE HEA

TER. 

•   DO NOT ROUTE POWER CORD BENEA

TH HEA

TER.

• 

SEE LOCAL

 BUILDING CODE 

AND MANUF

ACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED 

WHEN P

ASSING 

A CHIMNEY

 THROUGH 

A COMBUSTIBLE W

ALL

 OR CEILING.

• 

DO NOT P

ASS 

A CHIMNEY

 CONNECT

OR THROUGH 

A COMBUSTIBLE W

ALL

 OR CEILING.

• 

MINIMUM CLEARANCE BETWEEN SINGLE W

ALL

 CHIMNEY

 CONNECT

OR 

AND COMBUSTIBLE 

MA

TERIALS-18INCHES/455MM.  CLEARANCE MA

Y BE REDUCED BY

 THE USE OF LISTED PIPE SHIELDS, 

W

ALL

 PROTECT

ORS OR OTHER MEANS 

APPROVED BY

 LOCAL

 BUILDING OR FIRE OFFICIALS.

• 

COMPONENTS REQUIRED FOR MOBILE HOME INST

ALLA

TION: OUTSIDE 

AIR KIT

•   HORIZONT

AL

 CONNECT

OR NOT PERMITTED IN MOBILE HOMES

• 

BOTH CHIMNEY

 SYSTEM 

AND CONNECT

OR MUST BE LISTED T

O:

 

IN CANADA

 -  ULC S-641 LISTED CONNECT

OR 

AND ULC-S-629 LISTED CHIMNEY

 

IN USA

 -  UL-103 HT LISTED CONNECT

OR 

AND CHIMNEY

 

• 

USE COMPONENTS SPECIFIED IN P

ACIFIC ENERGY

 INST

ALLA

TION INSTRUCTIONS.

• 

APPLIANCE MUST BE INST

ALLED WITH PEDEST

AL

 OR LEG KIT 

ATT

ACHED.

• 

OPTIONAL

 COMPONENTS - F

AN KIT (part # 1

1140001), F

AN ELECTRICAL

 RA

TING: 1

15V

, 60HZ, 1.0 

AMP

•   DO NOT USE GRA

TE OR ELEV

ATE FIRE - BUILD WOOD FIRE DIRECTL

Y ON HEARTH.

•   DO NOT OVERFIRE - IF CHIMNEY

 OR CONNECT

OR GLOWS, 

YOU 

ARE OVERFIRING.

• 

CAUTION: RISK OF EXCESSIVE TEMPERA

TURES - OPERA

TE ONL

Y WITH FEED DOOR CLOSED.  OPEN 

TO FEED FIRE ONL

Y. - KEEP

 ASH DUMP

 CLOSED DURING FIRING OF THE HEA

TER. 

• 

KEEP

 FURNISHINGS 

AND OTHER COMBUSTIBLE MA

TERIALS WELL

 A

W

AY

 FROM HEA

TER.

• 

REPLACE GLASS ONL

Y WITH CERAMIC GLASS.

• 

COMBUSTIBLE FLOOR MUST BE PROTECTED BY

 A

 CONTINUOUS NON-COMBUSTIBLE MA

TERIAL

 

EXTENDED T

O THE FRONT

, SIDES 

AND BACK 

AS INDICA

TED.

•   INSPECT 

AND CLEAN CHIMNEY

 FREQUENTL

Y - UNDER CERT

AIN CONDITIONS OF USE, CREOSOTE 

BUILDUP

 MA

Y OCCUR RAPIDL

Y.

• 

THIS WOO

D HEA

TER NEEDS PERIODIC INSPECTION 

AND REP

AIR FOR PROPER OPERA

TION. - CONSUL

THE OWNER’S MANUAL

 FOR FURTHER INFORMA

TION. 

• 

IT IS 

AGAINST FEDERAL

 REGULA

TIONS T

O OPERA

TE THIS WOOD HEA

TER IN 

A MANNER INCONSIST

ANT 

WITH THE OPERA

TING INSTRUCTIONS IN THE OWNER’S MANUAL

*

   

AS TESTED - PIPE SHIELD MA

Y BE REQUIRED BY

 LOCAL

 AUTHORITIES.

**

 COMBUSTIBLE 

ALCOVE SIZE:  DEPTH - 3 FT

. / .91 M MAX., HEIGHT 6 ft. / 1.83 m MIN., 

• 

À UTILISER UNIQUEMENT 

AVEC DU COMBUSTIBLE SOLIDE. NE P

AS UTILISER D’AUTRES TYPES DE CARBURANT

•   INST

ALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INST

ALLA

TION ET D’OPÉRA

TION FOURNI 

AVEC L

’APP

AREIL..

• 

CONT

ACTEZ LES OFFICIELS DE LA

 CONSTRUCTION OU DE SER

VICE D’INCENDIE POUR DES INFORMA

TIONS QUANT 

AUX 

RESTRICTIONS. PERMIS D’INST

ALLA

TION ET INSPECTIONS DANS VOTRE RÉGION.

• 

NE RELIEZ P

AS CET 

APP

AREIL

 À UN CONDUIT DE CHEMINÉE DESSER

VANT DÉJÀ UN 

AUTRE 

APP

AREIL

 .

• 

UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET 

AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm.

• 

PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE 

ALIGNÉE PRÊTE À L

’EMPLOI 

AVEC DES COMBUSTIBLES SOLIDES.

• 

N’

OBSTRUEZ

 P

AS

 L

’ESP

ACE

 SOUS

 LE

 CAISSON

 DU

 POÊLE

• 

CONSUL

TEZ LE CODE LOCAL

 DE CONSTRUCTION ET LES INSTRUCTIONS DU F

ABRICANT QUANT 

AUX PRÉCAUTIONS À 

PRENDRE LORSQUE VOUS F

AITES P

ASSER UNE CHEMINÉE À TRA

VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE 

MA

TÉRIAUX COMBUSTIBLES.

• 

NE F

AITES P

AS P

ASSER UN RACCORDEMENT DE CHEMINÉE À TRA

VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE 

MA

TÉRIAUX 

• 

DÉGAGEMENT MINIMAL

 ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET T

OUT MA

TÉRIEL

 COMBUSTIBLE 

- 18 POUCES / 455 mm.  CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUY

AUX CLASSÉS, 

PROTECTEURS DE MUR OU 

AUTRES MOYENS 

APPROUVÉS P

AR LES OFFICIELS DE LA

 CONSTRUCTION OU DU SER

VICE 

D’INCENDIE DE VOTRE RÉGION.

 

CONNECTEUR HORIZONT

AL

 NON PERMIS DANS MAISONS MOBILES

• 

L’APP

ARIEL

 DOIT COMPORTER UN ENSEMBLE POUR PIEDST

ABLE OU SUR P

ATTES.

• 

PIÈCES REQUISES POUR INST

ALLA

TION EN MAISON MOBILE OU EN 

ALCÔVE:  NÉCESSAIRE 

D’APPROVISIONNEMENT D’AIR EXTÉRIEUR ET L

’UN DES RACCORDS SUIV

ANTS:  EN COMBINAISON 

AVEC L

’UN DES SYSTÈMES DE CHEMINÉE COMP

ATIBLES SUIV

ANTS: 

  

  AU

 CANADA

 - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE

• 

 PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE:  1

15V

, 60HZ, 1.0 

AMP

.  LE FIL

 

ÉLECTRIQUE NE DOIT P

AS ÊTRE PLACÉ SOUS LE POÈTE.  LE FIL

 ÉLECTRIQUE NE DOIT P

AS ÊTRE PLACÉ SOUS LE POÊLE

• 

ATTENTION:  RISQUE DE TEMPÉRA

TURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L

’ALLUMAGE DU 

POÈTE.

• 

OPÉREZ SEULEMENT LORSQUE LA

 PORTE D’ALIMENT

ATION EST FERMÉE. • OUVREZ SEULEMENT POUR 

ALIMENTER LE FEU.

• 

GARDEZ LES MEUBLES ET 

AUTRES MA

TÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.

• 

REMPLACES LA

 VITRE 

AVEC UNIQUEMENT DE LA

 VITRE CÉRAMIQUE.

 

TEL

 QUO ÉPROUVÉ UN PROTECTEUR DE TUY

AU PEUT ÊTRE REQUIS P

AR LES 

AUT

ORITÉS LOCALES

 

**

 DIMENSION D’ALCOVE COMBUSTIBLE:  PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M  MINIMUM.

 

LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ P

AR UN MA

TÉRIEL

 NON-COMBUSTIBLE T

OUT D’UNE PIÈCE QUI DOIT 

S’ÉTENDRE DE P

AR LE DEV

ANT

, LES COTÉS ET L

’ARRIÈRE TEL

 QU’INDIQUÉ.

• 

CET 

APPRAREIL

 DE CHAUFF

AGE 

AU BOIS DOIT F

AIRE L

’OBJETD’ENTRETIENS ET D’INSPECTIONS P

ÉRIODIQUES 

POUR UN FONCTIONNEMENT 

AD

ÉQUA

T. CONSUL

TEZ LE MANUEL

 D’UTILISA

TION POUR PLUS D’INFORMA

TION.

(T

ype 1 fl

oor 

pr

ot

ect

or - appr

ov

ed 

to UL1

61

8)

Minim

um 

20G

st

eel

Neo 2.5 LE_14119-32

3

100003380

Содержание NEO 2.5 LE

Страница 1: ...ty follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in your area Meets the Environmental Protection Agency s 2020 Particulate Emission Standards Cord Wood IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SERIAL Visit www pacificenergy net for the most recent version of this manual ...

Страница 2: ... IN THE AREA WHERE THE HEATER IS TO BE INSTALLED If smoke detectors have been previously installed you may notice that they are operating more frequently This may be due to curing of stove paint or fumes caused by accidentally leaving the fire door open Do not disconnect the detectors SAFETY NOTICE If this stove is not properly installed a house fire may result For your safety follow the installat...

Страница 3: ...D COMBUSTIBLE MATERIALS 18INCHES 455MM CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION OUTSIDE AIR KIT HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO IN CANADA ULC S 641 LISTED CONNECTOR AND ULC S 629 LISTED ...

Страница 4: ...e air inlet can be turned down substantially without excessive smoke generation Wood coals create very little creosote producing smoke 2 The cooler the surface over which the wood smoke is passing the more creosote will be condensed Wet or green wood contributes significantly to creosote formation as the excess moisture that is boiled off cools the fire making it difficult for the tars and gases t...

Страница 5: ...nderstood plan on how to handle a chimney fire 4 After the chimney fire is out the chimney must be cleaned and checked for stress and cracks before starting another fire Also check combustibles around the chimney and the roof The services of a certified installer Chimney Sweep from one of the associations listed below is strongly recommended to inspect and service your Chimney system NFI National ...

Страница 6: ...ents Lawn clippings yard waste Unseasoned wood Railroad ties Manure or animal remains Materials containing rubber including tires Materials containing plastic Construction or demolition debris Materials containing asbestos Waste petroleum products paints paint thinners or asphalt products Paper products cardboard plywood or particleboard These materials contain chlorides which will rapidly destroy...

Страница 7: ... future burns 2 To refuel adjust air control to high and give the fire time to brighten Open the door slowly this will prevent back puffing 3 Use wood of different shape diameter and length up to 18 457mm Load your wood endwise and try to place the logs so that the air can flow between them Always use dry wood 4 Do not load fuel to a height or in such a manner that would be hazardous when opening ...

Страница 8: ... your firebox and when fire has burned down and cooled remove excess ashes Leave an ash bed approximately 1 25 mm deep on the firebox bottom to help maintain a hot charcoal bed Ash Clean out system The ash dump handle is located behind the Lower Grill under the ash lip on the left hand side To access the handle pull the Lower Grill up to unlock then tip towards to you To operate ash dump pull hand...

Страница 9: ...t Parts List page 28 Do not substitute with any other type of Glass To remove broken glass undo the four retaining screws and remove clamps and frame noting position for re assembly Remove all particles of glass Be careful as they are very sharp Install new glass complete with gasket Replace frame clamps and screws CAUTION Do not overtighten tighten screws very carefully Do not clean glass when ho...

Страница 10: ...Top Heat Shield and mounting bolts Baffle Gasket Brick Rail Tabs and Brick Rails Air Riser Tube in the back of the firebox Blower The optional blower should be cleaned out a minimum every six months by using a vacuum on the grill openings in the back and bottom of the blower casing to remove any dust and debris Baffle Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has...

Страница 11: ...INSULATION REMOVED Baffle Removal 1 Remove retaining pin at the back of the firebox just under the baffle 2 Lift the Baffle up to disconnect from the Baffle Supply Tube 3 Pull the Baffle towards you then tilt it sideways to drop down and remove from firebox You may need to remove the opposite side brick rail to allow the Baffle to drop down To remove the Brick Rail remove the brick directly under ...

Страница 12: ...Dimensions 39 990mm 40 1 016m 29 735mm 24 1 4 615mm 6 1 8 155mm 29 735mm 6 1 8 155mm Figure 1 NEO 2 5 LE Dimensions Neo 2 5LE_141119 32 12 100003380 ...

Страница 13: ...nish With the pattern at the top guide the Side Panel s front tabs into the slots on the front of the Panel Mounting Brackets located on the side of the unit Pull towards the back to fully engage Figure 2 Using the screws provided attach the Panel to the unit Use the fibre washers between the panel and the screw head on enamel panels to prevent chipping Figure 3 Screw locations Figure 2 NEO 2 5 LE...

Страница 14: ...e 5 This protection is also required under the chimney connector and 2 51 mm beyond each side Canada Only Minimum Width 45 1 14m Minimum Overall Depth 49 3 8 1 25m 8 203mm 8 203mm 8 203mm 18 457mm Non combustible floor protector 16 406mm U S A Only Minimum Width 35 889mm Minimum Overall Depth 37 3 8 950mm Type 1 floor protector approved to UL1618 Minimum 20GA steel Non combustible floor protector ...

Страница 15: ...ncy NFI National Fireplace Institute in the United States CSIA Chimney Safety Institute of America in the United States and Canada WETT Wood Energy Technology Transfer in Canada or APC Association des Professionnels du Chauffage in Quebec 18 457mm 12 305mm 26 1 2 673mm 20 5 8 524mm 8 203mm 11 279mm 5 127mm 15 5 8 397mm 3 76mm 8 203mm 3 76mm 8 203mm 8 203mm 22 1 2 572mm 8 203mm 11 279mm 5 127mm 22 ...

Страница 16: ...29 LISTED CHIMNEY IN USA UL 103 HT LISTED CONNECTOR AND CHIMNEY When using a Double Wall Connector Use a listed double wall connector If a listed chimney and double wall connector are to be connected to the stove install all components as per the chimney connector manufacturer s installation requirements When using a Single Wall smoke pipe Connector The single wall pipe section must be If you are ...

Страница 17: ... mobile home installation optional for residential installation To draw outside air through the floor This hole must get its air from a ventilated crawl space or be extended with duct to the outdoors See Figure 7 Residential venting on page 18 The use of outside combustion air for residential installation requires the unit to be secured to the structure to prevent dislodging of the air duct Cut or...

Страница 18: ...set elbows and chimney section must be screwed together by at least three sheet metal screws per joint The chimney must be suitably supported by the chimney manufacturer s listed offset support 44 1118 mm Minimum 4 102mm diameter air inlet with rodent screen If the crawl space is well ventilated it is not necessary to extend air inlet to outside Attach to floor for mobile homes Unit may be harder ...

Страница 19: ...or 48 1219 mm Hooded vent or 90 elbow turned down Ensure that the Masonry chimney meets all National Fire Protection Association and local building codes Have the chimney cleaned and inspected by a professional to ensure there are no cracks weak mortar or other signs of deterioration See pipe manufacturers installation instructions for further information Approved Through Wall Installation 12 305m...

Страница 20: ...ce between the outer wall of the chimney length and combustibles The inner end of the chimney length shall be flush with the inside of the masonry chimney flue and shall be sealed to the flue and to the brick masonry penetration with non water soluble refractory cement Supports shall be securely fastened to wall surfaces on all sides Fasteners between supports and the chimney length shall not pene...

Страница 21: ...24 in 0 61 mm in thickness with a ventilated thimble minimum 24 gauge 0 024 in 0 61 mm in thickness having two 1 in 25 4 mm air channels separated from combustibles by a minimum of 6 in 152 mm of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge 0 024 in 0 61 mm in thickness Supports shall be securely fastened to wall surfaces on all ...

Страница 22: ...ommended NFI National Fireplace Institute in the United States CSIA Chimney Safety Institute of America in the United States and Canada WETT Wood Energy Technology Transfer in Canada or APC Association des Professionnels du Chauffage in Quebec Clearances This heater must be installed with listed double wall connector and compatible ULC S629 or UL 103HT listed chimney system Clearances to combustib...

Страница 23: ...uto and set the speed control to your desired setting This will allow the fan to turn on as the stove heats up to operating temperature It will also shut the blower off after the fire has gone out and the unit has cooled to below a useful heat output range Manual To manually operate the blower set the rocker switch to Man and set the speed control to your desired setting This will bypass the tempe...

Страница 24: ...On one of the side walls stand three A bricks vertically and push them back so that they make contact with the A bricks on the rear wall Then place a C brick on top of an A brick Figure 17 4 Slip an A brick horizontally on top of the center and near A bricks Insert this brick behind the tab as shown in Figure 18 Figure 15 Right side rear wall brick A placement Figure 16 Left side rear wall A and B...

Страница 25: ...20 8 Place a C brick on the firebox floor in front of the ash dump and up against the A brick located on the left side of the firebox floor Figure 21 9 Finish by placing two A bricks on the right side of the firebox floor followed by the remaining D brick placed in the center of the firebox in front of the B brick Note there will be one full sized A brick left over as a spare Figure 19 Back row fl...

Страница 26: ...et Check door latch Low Heat Output 1 Wood may be wet Check wood and use drier wood if required 2 Fire too small Build a larger fire Open draft control to increase burn rate 3 Draft too low Chimney plugged or restricted Inspect and clean Won t Burn Overnight 1 Air control set too high Set control lower 2 Not enough wood Unsplit wood is preferred for overnight burns 3 Draft too high Excessive chimn...

Страница 27: ...Neo 2 5 LE_14119 32 27 100003380 ...

Страница 28: ... Primary c w Spring Washer and Cap 80000838 5 Ash Lip Cast Met Black 80000241 6 Lower Grill NEO 2 5 80000849 7 Door Gasket Kit 80002439 8 Glass Retainer 80000246 9 Replacement Glass 80000240 10 Door Handle Assy 80001754 11 Door NEO 2 5 Met Black 80000253 12 Gasket 2 Baffle Tube 10 pack 80000365 13 Baffle Pin 10 pc 80000364 14 Baffle 80000247 15 Brick Rail 80000251 16 Heat Shield 80002441 17 Ash Du...

Страница 29: ...1 16 14 23 24 3 5 4 2 25 1 6 15 7 17 20 19 22 8 9 11 10 18 21 13 12 2 26 Figure 23 NEO 2 5LE Parts Neo 2 5 LE_14119 32 29 100003380 ...

Страница 30: ...Neo 2 5LE_141119 32 30 100003380 ...

Страница 31: ...Neo 2 5 LE_14119 32 31 100003380 ...

Страница 32: ...ttp www pacificenergy net For additional technical support please contact your dealer Printed in Canada 2019 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws ...

Отзывы: