Figure 22: Camden corner framing.
D
E
F
A
C
B
Figure 23: Casco Camden mantel
clearances.
CASC.BODYB
CMDN.BODYB
Installer Information
* Mantel clearances as measured from the bottom of the
fireplace to the bottom of the lintel.
CASCO
CAMDEN
A
34”
34”
45”
40”
B
34”
34”
43.5”
39.5”
C
34”
34”
42”
39”
LOUVERED
CONTOURED
LOUVERED
CONTOURED
CASCO
CAMDEN
ENCLOSED SIDE WALL
1.75”
1.75”
ENCLOSED BACK WALL
NCR*
NCR*
ENCLOSED CEILING
4”
4”
ENCLOSED FRONT WALL
NCR*
NCR*
EXPOSED SIDE WALL
8”
8”
VENT ENCLOSURE
1”
1”
EXTERIOR SOFFIT
30”
30’
Minimum Clearance to Combustible Materials
* NCR stands for “No Clearance required”. You may use combustible
materials in direct contact with the appliance on these surfaces.
Clearances to Combustibles
“Louvered” and “Contured” refer to the style of “Fronts” avail-
able to both the Casco and Camden fireplaces. Because of
the different dimensions and BTU output of the two fireplaces,
the distance between the bottom of the fireplace and the bot-
tom of the mantels will vary depending on how far the mantel
extends from the wall. Use the above tables to determine the
correct position of the mantel.
D
12”
E
9”
F
6”
Distance that mantel extends from wall
17
5055.634-B
251115-44